![JDS Uniphase SmartClass E1 Скачать руководство пользователя страница 96](http://html2.mh-extra.com/html/jds-uniphase/smartclass-e1/smartclass-e1_user-manual_3644301096.webp)
Chapter 7
Test Results
E1 Results
80
SmartClass E1 Tester User’s Guide
Interface results
The Interface category lists results related to the physical interface.
describes the results that appear in the Interface category.
Ref Clk Frequency
Frequency of the reference clock
Rx Level Vpp
Current receive level, in volts peak-to-peak
Rx Level dBnom
Current receive level, in dB nominal
Code Errors
Number of detected violations of the selected encoding
method.
Code Error Rate
Ratio of code errors received to the total number of bits
received
Timing Slips
Number of bit slips (±) counted when the E1 test signal slips
from the E1 reference signal after both signals are present
simultaneously. Counts from 0 to + or - 255, and then rolls
over to 0. Resets to 0 if signal present is lost on the ana-
lyzed E1 circuit or on the reference E1 circuit. A positive
results indicates that the analyzed E1 circuit is faster than
the reference E1 circuit.
Frame Slips
Number of frame slips (absolute value) counted when the
E1 test signal slips from the E1 reference signal after both
signals are present simultaneously.
Table 11
Signal test results (Continued)
Result
Description
Table 12
Interface test results
Result
Description
LOF Alarms
Number of times the LOF condition was detected
LOF Seconds
Seconds in which loss of framing was detected
AIS Alarms
Number of alarm indication signals detected
AIS Seconds
Number of seconds in which AIS was detected
RDI Alarms
Number of Remote Defect Indication alarms
RDI Seconds
Number of seconds in which RDI was detected
MF AIS Alarms
Number of Multi Frame Alarm Indication Signals
detected
MF AIS Seconds
Number of seconds in which MF-AIS was detected
MF RDI Alarms
Number of Multi Frame Remote Defect Indication
alarms detected
MF RDI Seconds
Number of seconds in which MF-RDI was detected
FAS BIT Errors
Number of errored Frame Alignment Signal bits
detected
FAS BIT Error Rate
Ratio of errored FAS bits to the total number of FAS
bits received
FAS Word Errors
Number of errored FAS words detected
MFAS Word Errors
Number of errored MFAS words received since initial
frame sync
Содержание SmartClass E1
Страница 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 2: ......
Страница 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 6: ...iv SmartClass E1 Tester User s Guide...
Страница 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Страница 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Страница 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Страница 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Страница 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Страница 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Страница 143: ......