Chapter 5
Datacom Testing
Frame Relay testing
70
SmartClass E1 Tester User’s Guide
3
If you need to specify other settings for the test, press
Cancel
to return to
the Configuration menu.
The frame relay LMI settings are configured.
Configuring the trace
settings
You can use the E1/Datacom Tester to capture and decode LMI messages.
Captured messages can be displayed as link trace results in text, hexidecimal,
or text and hexidecimal format. The following procedure describes how to set
the trace settings.
To specify trace settings
1
If you haven’t already done so, launch the Frame Relay application (see
“Launching the Frame Relay application” on page 64
2
On the Configuration menu, select
FR Trace Settings
, and then specify
the following settings:
3
If you need to specify other settings for the test, press
Cancel
to return to
the Configuration menu.
The trace settings are configured.
Specifying flow control
settings
Determine whether the device you will connect the E1/Datacom Tester to uses
flow control. If so, you can configure the E1/Datacom Tester for out-of-band
flow control.
To specify flow control settings
1
If you haven’t already done so, launch the Frame Relay application (see
“Launching the Frame Relay application” on page 64
2
On the Configuration menu, select
Flow Control Settings
.
3
Select
OOB Flow Ctrl
, and then select
On
to enable out of band flow
control, if necessary.
4
If you need to specify other settings for the test, press
Cancel
to return to
the Configuration menu.
The flow control settings are specified.
Setting
Parameters
Decode Level
Select one of the following decode levels:
–
Simple
: Displays basic decode information for
each trace message.
–
Verbose
: Displays detailed decode information for
each trace message.
Display Type
Select how trace messages will be displayed:
–
Text
: Displays the trace messages as text.
–
Hex
: Displays the trace messages in a hexidecimal
format.
–
Text & Hex
: Displays the trace messages in both
text and hexidecimal formats.
Содержание SmartClass E1
Страница 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 2: ......
Страница 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 6: ...iv SmartClass E1 Tester User s Guide...
Страница 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Страница 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Страница 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Страница 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Страница 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Страница 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Страница 143: ......