Chapter 5
Datacom Testing
Specifying test settings
SmartClass E1 Tester User’s Guide
55
Specifying polarity settings
The following procedure describes how to configure clock and data polarity
settings.
To specify polarity settings
1
If you haven’t already done so, launch the Data Communication applica-
tion (see
“Launching the datacom application” on page 52
).
2
On the Configuration menu, select
Polarity
, and then specify values for
the following settings:
You have finished specifying the polarity settings.
Specifying a BERT pattern
You can specify a specific BERT pattern for your test.
To specify a BERT pattern
1
If you haven’t already done so, launch the Data Communication applica-
tion (see
“Launching the datacom application” on page 52
).
2
On the Configuration menu, select
BERT Pattern Settings
, and then
choose a pattern:
Setting
Parameter
RxClock Polarity
Specify the polarity for the Rx Clock:
–
Normal
. Uses the phasing specified by the inter-
face standard.
–
Inverted
. Uses the inverse of the phasing specified
by the interface standard.
TxClock Polarity
Specify the polarity for the Tx Clock:
–
Normal
. Uses the phasing specified by the inter-
face standard.
–
Inverted
. Uses the inverse of the phasing specified
by the interface standard.
RxData Polarity
Specify the polarity for the received data:
–
Normal
. Uses the phasing specified by the inter-
face standard.
–
Inverted
. Uses the inverse of the phasing specified
by the interface standard.
TxData Polarity
Specify the polarity for the transmitted data:
–
Normal
. Uses the phasing specified by the inter-
face standard.
–
Inverted
. Uses the inverse of the phasing specified
by the interface standard.
Pattern
Description
PRBS 63
Selects the 2
6
-1 pseudorandom pattern, which
generates a maximum of 5 sequential 0s and 6
sequential 1s.
PRBS 511
Selects the 2
9
-1 pseudorandom pattern, which
generates a maximum of 8 sequential 0s and 9
sequential 1s.
Содержание SmartClass E1
Страница 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 2: ......
Страница 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 6: ...iv SmartClass E1 Tester User s Guide...
Страница 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Страница 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Страница 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Страница 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Страница 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Страница 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Страница 143: ......