Chapter 5
Copper Testing
Cord compensation
SmartClass ADSL/Copper Tester User’s Guide
33
battery/wetting current. Although the detector will work with voltage on a
pair, accuracy will be reduced. In addition, the detector works best when
the last coil is followed by at least 1200 feet (336 meters) of cable.
The test begins automatically and results appear on the screen.
To learn what your results mean, see
Chapter 7 “Interpreting Test Results”
.
You can save your results, if desired. See
.
You are finished performing measurements.
Cord compensation
For greatest accuracy, JDSU recommends that you perform a cord compensa-
tion to remove the effects of the test leads from the test measurements. There
are two scenarios for compensation: all leads open and all leads shorted.
To compensate for the cords
1
From the main menu, select
COPPER TEST
.
2
Press the
4
key to select SETUP.
The SETUP menu appears.
3
Press the
8
key to select CORD COMP.
4
Follow the instructions on the screen to connect the black, red, and green
leads to perform test lead compensation.
5
Press the # key to start.
The compensation stops automatically when finished.
Calibrating the unit
On occasion, your unit may need calibration to maintain accuracy of the copper
test functions. This built-in calibration replaces the need for factory calibration.
To calibrate the unit
1
From the main menu, select
COPPER TEST
.
2
Press the
5
key to select CALIBRATION.
An acknowledgement screen appears.
3
Select
OK
to continue the calibration.
The ADSL/Copper Tester performs a self calibration. The self-calibration
values are stored in internal memory.
4
Press Cancel to return to the
COPPER TEST
menu.
Содержание SC-ADSL-A
Страница 1: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Страница 2: ......
Страница 3: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Страница 6: ...iv SmartClass ADSL Copper Tester User s Guide...
Страница 14: ...About this Guide Conventions xii SmartClass ADSL Copper Tester User s Guide...
Страница 26: ...Chapter 2 Quick Tour Using the keypad 12 SmartClass ADSL Copper Tester User s Guide...
Страница 32: ...Chapter 3 Instrument Settings Restoring factory defaults 18 SmartClass ADSL Copper Tester User s Guide...
Страница 48: ...Chapter 5 Copper Testing Calibrating the unit 34 SmartClass ADSL Copper Tester User s Guide...
Страница 58: ...Chapter 6 Configuring Tests Loading a configuration 44 SmartClass ADSL Copper Tester User s Guide...
Страница 74: ...Chapter 7 Interpreting Test Results Saving results 60 SmartClass ADSL Copper Tester User s Guide...
Страница 84: ...Chapter 9 Troubleshooting Resolving problems 70 SmartClass ADSL Copper Tester User s Guide...
Страница 89: ......