Selecting measurement mode
Procedure
1.
Press the
MODE
hard key.
2.
Select
More (1/2) > Power Meter > Internal RF Power Meter
.
Setting frequency
You need to set the frequency range to be measured either with the center frequency and span or with
the start and stop frequencies. You can also set the frequency with the channel number and span.
Procedure
To set the center frequency and span:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Freq
.
3.
Press the
Center Frequency
soft key.
4.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow keys.
5.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
6.
Press the
Span
soft key, and then do one of the following:
–
To set the span manually, select
Span
, enter a value, and then select the unit.
–
To set the span automatically, select
Full Span
,
Zero Span
, or
Last Span
as needed.
NOTE
The
Zero Span
option is available only in the Spectrum mode. If you have selected
Zero
Span
, select
TRIGGER
> Free Run
,
External
,
GPS
,
Video
, or
Display Position
.
To set the start and stop frequencies:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Freq
.
3.
Press the
Start Frequency
soft key.
4.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow keys.
5.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
6.
Press the
Stop Frequency
soft key.
7.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow keys.
8.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
To set the channel number and span:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Channel
.
3.
To select the standard channel, complete the following steps:
a.
Press the
Channel Std
soft key. The standard channel window appears.
See
“Appendix C – Band, frequency & channel standard” on page 571 for more information.
b.
Select the band to be measured by using the rotary knob, the arrow keys, or the
Page
Up/Page Down
soft keys.
c.
Press the
Select
soft key or the rotary knob to confirm the selection.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...