JD780A Series Analyzers
Using T1 Analyzer
529
Monitoring transmission
Making a test
Procedure
To select the measurement mode:
1.
Press the
MODE
hard key.
2.
Press the
E1/T1 Analyzer
soft key.
3.
Select
T1 Analyzer > Monitoring
.
To configure measurement parameters:
1.
Press the
MEASURE SETUP
hot key.
2.
Press the
RX Mode
soft key, and then select the receiver input option from the following choices:
–
Terminate
: Provides 100-ohm nominal input impedance, according to the framing, line
code, and BER pattern settings.
–
Bridge
: Provides input impedance greater than one kilohm for in-service monitoring,
bridging the receiver input across lines that are terminated elsewhere in the network.
–
Monitor
: Provides 100-ohm nominal input impedance for the in-service monitoring of T1
lines.
3.
Toggle the
Framing
soft key between
SF-D4
and
ESF
and select the framing type for your
receiver setting:
–
SF-D4 (Super Frame-D4):
Group of 12 frames, used to align equipment for framing.
–
ESF (Extended Super Frame):
Group of 24 frames, used to align equipment for framing.
4K for a maintenance channel (Facilities Data Link), 2K for CRC-6 checksum, and 2K for
framing/synchronization.
NOTE
If the framing type does not match with your receiver setting, a framing alarm occurs.
4.
Toggle the
Line Code
soft key between
AMI
and
B8ZS
and select the line code type to send an
T1 signal:
–
AMI:
It stands for Alternate Mark Inversion. A line code uses one three level signal to
convey binary digits in which successive binary ones (
“marks” or pulses) are of alternating
polarity, either positive or negative, equal in amplitude. A binary zero
(“space”) is
transmitted as no pulse or zero amplitude.
–
B8ZS:
It stands for Bipolar with 8-Zero Substitution. A coding scheme in which the
transmitter "substitutes" a fixed pattern of ones, zeros, and BPVs in place of 8 consecutive
zeros.
To start or stop monitoring:
1.
Press the
MEASURE
hot key.
2.
Press the
Monitoring
soft key, and then select the monitoring option as needed:
Start
,
Stop
, or
Clear
.
Optional
. You can save event records automatically by using the
Save Logging Data
soft key. See
“Using save” on page 31 for more information.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...