ACLR
The Adjacent Channel Leakage power Ratio (ACLR) measures the amount of interference or power in
an adjacent frequency channel according to the standards.
Setting measure setup
After configuring test parameters as described in the
“Configuring test parameters” on page 415, you
can continue your measurement.
Procedure
1.
Press the
MEASURE SETUP
hot key.
2.
Press the
Slot Number
soft key, and then select the time slot number to be displayed:
TS0
,
TS1
,
TS2
,
TS3
,
TS4
,
TS5
, or
TS6
.
3.
Optional
. To set the delay, complete the following steps:
a.
Press the
Delay
soft key to set the amount of delay in µs.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Press the
µs
soft key.
NOTE
The Delay setting is used only when there is a time offset in the signals to be measured.
Measurement example
Figure 209
ACLR measurement with TD-SCDMA signal analyzer
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See
“Setting limit for RF tests” on page 428 for more
information.
Multi-ACLR
The Multi-ACLR measurement is used to perform multi-channel ACLR measurements with as many
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...