Chapter 5
Launching a reflectometry test and displaying results
Saving the trace(s) and generating a report
72
User Manual
770000102/08
–
If in the File Setup page (
S
ETUP
>
File
), the parameter
File Content
is defined with
All Traces
, one single .msor file and one single txt/
pdf report will be generated, bringing together all traces.
Example: if 3 traces are displayed in overlay, one single
.msor
file
and one single txt/pdf file (with one trace per page; except if the
results table is too long for one page) will be saved.
Opening a
report
1
To open the report, press
F
ILE
hardkey
2
In the
Explorer
page, in the directory selected, select the file/report.
The file name is:
For the txt file:
trace file_sor.txt
For the pdf file:
trace file.sor.pdf
3
Press
Load
.
The file opens on the T-BERD/MTS.
Fig. 44
PDF report
MTS2100 4100 Module US rev08.book Page 72 Jeudi, 1. août 2013 1:43 13