RS3 SYSTEM
jcm
technologies
10
3.
Operation
D1 and D2 LEDs of the transmitter will pass to battery saving mode (off) in 25 maneuvers after pressing PROG on
the transmitter. They can re-awaken again pressing the PROG button on the transmitter.
In order to detect obstacles, the RadioSens3 system compares the behaviour of the door in each maneuver with a
previously learned one when installing the equipment.
Normal operation of the system will only be allowed after a satisfactory learning of door movement. The control
panel will not allow the door to move if this learning has had errors or has not been done.
The RadioSens3 system has some conditions of use:
- The closing movement must start with the door fully open. It is not allowed to close the door from
intermediate points.
- If the door is half open, only the opening movement is allowed.
In order to adapt the operation of the system to the irregular conditions of the floor, the equipment can be inhibited
in some point at the end of the travel of the door. In the inhibition zone, obstacles will not be detected.
Setting the inhibition point is optional. In case it is desired, it can be fixed in two ways: automatically or manually.
If the inhibition point is set automatically, put the switch SW1: 2 to ON. During the programming of the maneuver
the equipment will automatically detect the ground and set the inhibition point automatically.
If the inhibition point is set manually, proceed as defined in the control panel manual.