P/N 960-000186R_Rev. A {EDP #253995}
© 2016, JAPAN CASH MACHINE CO., LTD.
6
RDM-100™ Series Retail Deposit Module
Environmental Specifications
Electrical Specifications
Structural Specifications
Table 3
RDM-100 Environmental Specifications
Operating Temperature:
+5ºC to +45ºC (41ºF to 113ºF)
*
*. Depends on hydrothermal conditions.
Storage Temperature:
-20ºC to +60ºC (-4ºF to 140ºF)
*
Relative Operating Humidity:
20% to 80% RH (non-condensed)
Relative Storage Humidity:
10% to 90% RH (non-condensed)
Visible Light Sensitivity:
Avoid light on the Banknote Insertion/Return Slots having an Illumination
index of 3000 Lux or less and if warm color incandescent light range
radiant of 0 to 45 degrees from all sides or if light from a Mercury Lamp a
radiant angle between 10 to 85 degrees
Installation:
Indoors Only (Built-in)
Fixture material/shape must endure 55kg weight without distortion
Table 4
RDM-100 Electrical Specifications
Supply Voltage
*
:
*. Use a Current Source Limiting Power Supply
24V DC ±10%
Current Consumption:
24V DC
•
Standby = 0.4A
•
Operation = 3.2A
•
Peak = 4.7A
Table 5
RDM-100 Structural Specifications
Weight:
Unit: Approximately 17kg (37.48lbs.)
Mounting:
Built-in
Outside Dimensions:
See “Entire Unit Outside Dimensions” on page 33 of this Manual
0
20
30
50
40
100
90
80
70
60
50
40
30
20
10
0
10
Hydrothermal Condition Table
Humidity
[%R
H
]
Temperature [ºC]
Allowable
and Humidity Range
45ºC/40RH%
40ºC/80RH%
10ºC/20RH%
5ºC/40RH%
Operating Temperature