3 INSTALLATION
This section provides installation and operating
instructions for the RDM-100 Banknote Validator
unit. The information within this section contains
the following features:
• Installation Procedure
• RDM-100 Installation Dimensions
Installation Procedure
To prepare the RDM-100 to Cash Box mounting
platform, six (6) holes are required to attached the
Rail Brackets, four (4) holes to install the Cash Box
Transport Guide Frame and a 123x42mm rectangle
cutout for placing the Cash Box Transport Assem-
bly (
U
NIT
I
NSTALLATION
Perform the following steps to install the RDM-100
Unit:
1. Confirm that the Rail Brackets (Figure 6
a
) were
installed on both sides of RDM-100 Unit.
2. Position the RDM-100 Unit to align the Rail
Bracket Installation Holes on the Cash Box Ceil-
ing to the Rail Brackets Holes. Attach the Rail
Brackets to the Cash Box Ceiling with the six (6)
M4x8 (or greater) Screws with Washers (Figure 7
a
1
to
a
6
).
3. Withdraw the RDM-100 Unit from the home
position on the Cash Box Ceiling.
Figure 5
Set Up Holes
4xM4 Tapping Hole
(or 4xØ4.5 Hole)
6xM4 Tapping Hole
Cash Box
Ceiling
Rectangle Hole
(123mm x 42mm)
Figure 6
Figure 6
Rail Brackets Confirmation
a
NOTE: There are three (3) Installation
Holes on each Rail Bracket.
Figure 7
Rail Brackets Holes
a
1
a
2
3
a
6
5
a
4
Cash Box
Ceiling
Figure 8
Figure 8
Unit Withdrawal