background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

5/37

LED DEVIL II

Important: On the master unit the DMX address MUST be set to 001.

(first DIP switch = ON, all other are

OFF)

The slave units can have any DMX address value but NOT 001!

You can inverse the behavior of one or more slave units by changing the position of DIP-switch n°10 on
these slaves. Just try it and see if the effect becomes better. Changing DIP-switch n°10 on the master has
no effect.

3. Connect the optional CA-8 controller for more control:

The CA-8 controller can only be used in standalone or master/slave mode. Connect the
controller to the jack input of the first unit (master). Now you can control all the connected
units:

Stand by

Blackout the unit (LED ON)

Function

Push for

1. strobe function
2. 2 light strobe
3. Sound strobe

Rotation speed selection

1-8

Mode

Musical mode (LED OFF)

automatic mode(LED ON)

4. DMX-mode:

When the units are connected in DMX-mode, they can be controlled using the following
DMX-charts:

1 CHANNEL MODE

3 CHANNEL MODE

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

6/37

LED DEVIL II

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning products.

Always dry the parts carefully.

Clean the external optics at least once every 30 days.

Clean the internal optics at least every 90 days.

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

Mains Input:

AC 100V ~ 240V, 50/60Hz

Power consumption :

23Watt

Max. Link up capacity IEC in/outputs:

50pcs

Fuse:

250V T6,3A slow blow (20mm glass)

Sound Control:

Internal microphone

DMX connections:

3pin XLR male / female

DMX channels used:

1 + 3 channels

Lamp:

1x RGBW LED 10Watt

Size:

172 x 215 x 195 mm

Weight:

3,3kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

Содержание Led Devil II

Страница 1: ...Groot Bijgaarden Belgium Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienung...

Страница 2: ...s normas vigentes no seu pa s WARNING DANGER never expose the lens to direct sunlight even for a short period This may damage the light effect or even cause fire ATTENTION DANGER n exposez jamais la l...

Страница 3: ...rmance or may even cause damages This unit is for indoor use only Don t place metal objects or spill liquid inside the unit Electric shock or malfunction may result If a foreign object enters the unit...

Страница 4: ...o make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled pe...

Страница 5: ...orroded Housings fixations and installations spots ceiling truss suspensions should be totally free from any deformation When an optical lens is visibly damaged due to cracks or deep scratches it must...

Страница 6: ...s minutes pour laisser l appareil s adapter la temp rature ambiante lorsqu il arrive dans une pi ce chauff e apr s le transport La condensation emp che l appareil de fonctionner mani re optimale et el...

Страница 7: ...iau ou liquide inflammable L appareil doit tre fix 50cm minimum des murs situ s proximit L appareil doit tre hors de port e du public et en dehors des zones de passage de personnes ou des zones o le p...

Страница 8: ...ilis pour les modes autonome et ma tre esclave Connectez le contr leur au jack d entr e du premier appareil ma tre Vous pouvez maintenant contr ler tous les appareils connect s Stand by L appareil LED...

Страница 9: ...ruikt in lichtshows Een extreem compact DMX gestuurd LED effect Dit krachtige opvallende Led effect gebruikt 3 optische schijven voor het bekomen van een ongelooflijk briljant en innovatief licht effe...

Страница 10: ...ar beschadigd zijn CAUTION WAARSCHUWING Om het risico op elektrocutie zoveel mogelijk te vermijden mag u nooit de behuizing verwijderen Er bevinden zich geen onderdelen in het toestel die u zelf kan h...

Страница 11: ...te stellen Hoe de DIP schakelaars gebruiken om het gewenste DMX startadres in te stellen Elk van de eerste 9 DIP schakelaars stemt overeen met een bepaalde DMX waarde DIP 1 2 3 4 5 6 7 8 9 10 Waarde...

Страница 12: ...EDIENUNGSANLEITUNG JB SYSTEMS 20 37 LED DEVIL II BEDIENUNGSANLEITUNG Vielen Dank dass Sie sich f r den Erwerb dieses JBSystems Produkt entschieden haben Bitte lesen Sie diese Bedienungsanleitung sorgf...

Страница 13: ...ile berlassen Sie Reparaturen dem qualifizierten Kundendienst Das Blitzsymbol im Dreieck weist den Benutzer darauf hin dass eine Ber hrungsgefahr mit nicht isolierten Teilen im Ger teinneren die eine...

Страница 14: ...Schalter kombinieren um gleich welche Startadresse zwischen 1 und 512 zu erhalten Anfangsadresse 01 Schalter 1 ON Werte 1 Anfangsadresse 04 Schalter 3 ON Werte 4 Anfangsadresse 07 Schalter 1 2 3 ON We...

Страница 15: ...d lea estas instrucciones de funcionamiento detenidamente antes de comenzar a utilizar esta unidad CARACTER STICAS Esta unidad est a prueba de interferencias de radio Este producto cumple los requisit...

Страница 16: ...realizar modificaciones no autorizadas en la unidad Importante Nunca mire directamente a la fuente de luz No utilice el efecto en presencia de personas epil pticas CAUTION PRECAUCI N Para reducir el...

Страница 17: ...es DIP corresponden a cierto valor DMX DIP 1 2 3 4 5 6 7 8 9 10 Valor 1 2 4 8 16 32 64 128 256 OFF 3CH DMX mode ON 1CH DMX mode Puede combinar los valores de estos interruptores para que se conviertan...

Страница 18: ...MANUAL DO UTILIZADOR Obrigado por ter adquirido este produto da JB Systems De modo a tirar total proveito das possibilidades deste produto por favor leia este manual com aten o CARACTER STICAS Esta un...

Страница 19: ...quaisquer altera es n o autorizadas unidade Importante Nunca olhe directamente para a luz N o utilize este efeito luminoso na presen a de pessoas epil pticas CAUTION ATEN O De forma a evitar o risco d...

Страница 20: ...1 2 3 4 5 6 7 8 9 10 Valor 1 2 4 8 16 32 64 128 256 OFF 3CH DMX mode ON 1CH DMX mode Pode combinar os valores destes interruptores para tornar qualquer endere o inicial entre 1 e 512 Endere o Inicial...

Страница 21: ...r para limpar o interior da unidade uma vez por ano De forma a optimizar a projec o de luz limpe as lentes pticas internas e externas e ou espelhos periodicamente A regularidade das limpezas depende d...

Отзывы: