- The unit notifies through both the display
and the LED when filters need maintenance.
- To replace the filters, first turn the fume
extractor off. Then remove the cover by
opening the side closures of the casing.
- If once the pre-filter has been changed the
saturation indicator is on, it means that the
compact filter is already saturated and must
be replaced too.
- The duration of the compact filter is 1 year
maximum once its packaging is opened.
- Once the compact filter has been replaced,
the filter counter must be reset.
(Main Menu > Filter > Reset)
- If the display shows an error message when
the equipment is switched on, it is probable
that the cover and casing connectors are
dirty and making false contact between
them. Remove the cover again and clean
both connectors.
Replacement
Read safety guidelines to do the equipment maintenance securely.