- 18 -
P9
6.2 FACTORY DEFAULTS - Factory settings
To reset P9 Beamspot to the factory settings, go to the menu item FACTORY DEFAULTS, LOAD
DEFAULTS. After confirming the security prompt SURE? with pressing “ENTER” for 2 seconds,
all parameters are reset to the factory settings.
6.3 USER DEFAULTS - User settings
If the user has set the P9 Beamspot in the PERSONALITY menu to their personal settings,
these can be saved and loaded in the USER DEFAULTS menu. In order to prevent unintentional
alteration of the data, you must enter the following password during the saving process: Buttons
"ESC DOWN UP ENTER".
6.4 DMX / NET ADDRESS - DMX addressing / Artnet addressing / sACN addressing
The DMX addressing can be done either directly in the display. Press the "UP" or "DOWN"
button to set the desired DMX address. The value is confirmed with the "ENTER" key. However,
the DMX addressing can also be done within the menu item DMX / NET ADDR, and there under
DMX ADDRESS.
To set the Artnet address, the menu item ARTNET ADDRESS must be selected in the DMX /
NET ADDR menu. The Artnet address can now be set using the UP / DOWN buttons. The Artnet
address is displayed in the form 000.00.00. This display corresponds to: Net.Subnet.Universum.
The sACN address can then be selected in the DMX / NET ADDR -> sACN ADDRESS menu. The
address can now be set using the UP / DOWN buttons. The sACN address is displayed in the
form 00000.
6.5 PERSONALITY - Personal settings
DMX INPUT CONFIG
In this menu item the options WIRELESS and NETWORK are available.
Under WIRELESS -> ON / OFF the factory-installed radio DMX receiver module of Lumen-Radio
can be activated or deactivated and via WIRELESS -> UNLINK the connection to the connected
transmitter can be deleted. In order to connect the fixture to a transmitter, wireless must be
set to ON on the fixture and the connection button must be pressed briefly on the transmitter.
The transmitter is now looking for all fixtures where wireless is enabled and fixtures that are not
connected to a transmitter. If the P9 Beamspot has successfully connected to the transmitter, the
display shows a level indication of the current reception quality. If the P9 Beamspot is additionally
connected via the DMX / etherCON connection sockets, these signals have priority over the
radio link. Using the key shortcut ESC and DOWN, pressed in the main menu, the headlamp can
be booked out of the booked transmitter (see page 22).
Under NETWORK -> MODE you can toggle between Artnet operation and sACN operation.
For network operation, the IP address of the spotlight must be selected or set under NETWORK
-> IP ADDRESS. Each headlight has a unique standard IP address.
INFO
SOFTWARE VER.
FIXTURE ID
TOT OP. TIME
TEMP BASE LCD
ACTUAL
MAX
RESET?
TEMP HEAD MAIN
ACTUAL
MAX
RESET?
TEMP HEAD DRV
ACTUAL
MAX
RESET?
TEMP BASE PS
ACTUAL
MAX
RESET?
TEMP HEAD LED
ACTUAL
MAX
RESET?
TEMP HEAD AMB.
ACTUAL
MAX
RESET?
TOT BAT CHARGE T.
TOT LAMP TIME