118
Section 8: Plumbing System
If an anode rod is mostly eaten away, replace it with a
new one. The water heater manufacturer recommends
replacement of the anode rod when consumption or
weight loss is greater than 75 percent.
Operating the water heater without the proper anode
rod protection will decrease tank life and will void
the tank manufacturer’s warranty on the tank. To
extend the anode life, drain the water from the water
heater tank whenever the RV is not being used. Avoid any extended time of non-use with
water in the tank.
To prevent a water leak when replacing the anode rod, a pipe thread sealant approved for
potable water (such as Teflon Tape) must be applied to the threads of the anode rod. Proper
application of a thread sealant will not interfere with the anode.
High altitude deration
Operation of the water heater at high altitudes may require derating. If the water heater is not
properly derated, lack of sufficient oxygen for combustion may produce improper burner
operation. Pilot outage caused by burner lift-off or sooting from a yellow burner may occur,
indicating the possibility of carbon monoxide. You may also notice a lack of efficiency in
heating the water because of incomplete combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
proper derating of the water heater. Change out of the orifice (derating) should be done by
the dealer or a qualified service agency.
Pressure & temperature relief valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1.
Turn off the water heater.
2.
Turn off the cold water supply line.
3.
Open a faucet in the recreation vehicle.
4.
Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
5.
Release the handle on the P&T valve - it should snap closed.
NOTE:
It is important that once the RV has returned to lower eleva-
tion (below 4500 feet) any high altitude deration or other adjustments
be reversed for proper operation of the water heater.
Anode rod replacement chart
Table of Contents
Maintenance Record
Содержание Greyhawk 2018
Страница 1: ...0188485 2018 2018 Class C Motorhome PRINTED ON RECYCLED PAPER Owner sManual...
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 12: ...2 Table of Contents Maintenance Record...
Страница 38: ...28 Section 2 Occupant Safety Notes Table of Contents Maintenance Record...
Страница 44: ...34 Section 3 Pre travel information Notes Table of Contents Maintenance Record...
Страница 68: ...58 Section 4 Vehicle Operation Notes Table of Contents Maintenance Record...
Страница 102: ...92 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Страница 154: ...144 Section 12 Interior Notes Table of Contents Maintenance Record...
Страница 164: ...154 Section 14 Additional Information Notes Table of Contents Maintenance Record...
Страница 168: ...158 Section 15 Additional Information Notes Table of Contents Maintenance Record...