5-6. DC/AC 10A measurement
1.
Insert the red test lead into the input terminal marked as “10A”.
2.
The measuring procedure is same as that of 5-5 section..
Mode except for OFF when electric field exceeding AC 110V is detected by the
metal piece sensor
Note:
For safety’s sake, the measuring time for high current should be
≤
10 second for each measurement and the interval time between
two measurement should be greater than 5 minutes.
When current measurement has been completed, disconnect the
connection between the testing lead and the circuit under test.
5-7 Temperature measurement
To measuring temperature must be use the Type Special Socket
:
MS3204.
1.
Set the rotary switch to the “TEMP” range. In this time, The
environment temperature value displayed on the LCD.
2.
Insert the Socket to the two “COM” and “TEMP” terminals.
3.
Insert the K-type temperature probe to the two insert holes of Socket.
User should be take note of it’s polarity.
4.
The measured temperature value will be displayed on the LCD.
5-8 Capactiance measurement
4.
Set the rotary switch to “capactiance” position.
5.
Insert the red test lead into the “
V
Ω
Hz”
input terminal and the
black test lead into the “
COM”
terminal.
6.
Connect the test leads across with the circuit under testing. The
measured value shown.
on the LCD display.
5-9 Detecting AC electric field [ NCV function]
The red LED on the upper area on the front panel lights up and then flickering
at all function
that is incoporated in the inner upper area of front case.
It indicates a presence of AC voltage in an electrical cricuit or equipment
without touching them. Detectuib against in-wall outlet is possible.
NOTE: In the some time, when measuring AC voltage, the red LED is lights.
You should be ignore this.
6.
Maintenance
6-1. Replacing the battery
When meter display
the battery must be replace to maintain
normal operation.
①
Disconnect and remove all test probes from any live
source and meter.
②
Open the battery cover on the bottom case by
screwdriver.
③
Remove old battery and snap new one into battery
holder
warning
TO AVOID ELECTRICAL SHOCK, REMOVE TEST LEADS BEFORE OPENING
BATTERY COVER.
RISQUE DE CHOC ÉLECTRIQUE, RETIRER CORDONS DE MESURE D'OUVERTURE AVANT
couvercle des piles.