Ref doc :
330740F/EN
revision 01
29.09.2015
2 NO contacts
N0 contact
connection
terminals
Ind. light state
Off
Flashing
On steady
Static output
17
Safety relays inactive or
charger monitoring
contacts open or
remote control
activated
Not applicable
Remote control
inactive, charger
monitoring contacts
closed and safety
relays activated
Static output
48
- Safety outputs
activated
- System fault
Flashing regularly:
on standby for reactivation by
one of the ON pushbuttons
No output activation
authorization
Static output
58
Charger contacts
closed and relays
activated
- All outputs inactive
subsequent to a system
fault
- Error code.
One of the safety functions
does not allow activation of
safety outputs
- Flashing rapidly to indicate
that transmitter must be
activated.
- Flashing slowly during area
access inhibit condition
Safety outputs
activated
The 2 white indicator lights« V1 and V2 » indicate the state of the receiver safety functions.
o
Receiver state when transmitter is on its charger: "V1" on and "V2" off.
o
Receiver state when transmitter is active: "V1 and V2" on.
3.5 Presentation of charger
In addition to charging the transmitter battery, the charger also has a transmitter detection function for detection of
a transmitter when not used.
When any of programs 0 to 4 are selected, the 2 NO contacts must be wired on inputs S31-S32 and S33-S34. If
programs 8 or 9 are selected, the 2 NO contacts must be wired in series on input S31-S2 (See wiring diagram in
appendix).