Page 12 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
3.3.2 Positioning the infrared module UDF
3.4 Configuring the receiver
The receiver module inputs and outputs can be configured in accordance with your applications.
To configure this parameter, you must remove the front panel of the product.
3.4.1 Choice of receiver (RSRA) program
The receiver has 10 programs which are user-definable by two « B » selectors.
Selector
« B »
position
Reset mode
for
protection
circuits
« S11-S14 »
and « S21-
S24 » (1)
Reset
mode after
radio
emergency
stop (2)
wireless
Number of
wired
emergency
stops
Dangerous
area
access
control
IR startup
recommended
Remarks
0
Manual
Radio
2
NO
YES
1
Manual
Control
panel
2
NO
NO
2
Automatic
Radio
2
NO
YES
.
3
Automatic
Control
panel
2
NO
NO
4
Manual
Radio
2
NO
YES
Special application.
5
Not used
6
Not used
7
Not used
8
Manual
Radio
1
YES
YES
Receiver module controls access to dangerous
area with radio remote control.
9
Manual
Control
panel
1
YES
NO
Receiver module controls access to dangerous
area with radio remote control.