Gb
Fr
- 64 -
324501E
revision02
De
JP2
JP4
JP1
V1
V3
V2
JP3
ON
OFF
V1 V2 V3
JP1
JP2
JP3
V1 V2 V3
JP1
JP2
JP3
Once transmitter identity code was chosen and programmed, receiver relays must
be associated to transmitter buttons.
The receiver is equipped with 3 programming jumpers/microswitchies
JP1
,
JP2
and
JP3
and three LEDs with
V1
,
V2
and
V3
which give indication to the
user during programming procedures (
V1
is switched ON continuously when
receiver is powered).
5.4-
«
Customized
» transmitter buttons / receiver
relays association
The programming association procedure needs the
JP3
jumper/microswitch.
1- Switch off industrial receiver (ORRA or ORRS)
, the receiver on DIN rail
(ORRD) can remain power supplied during all the procedure.
2-
For the ORRS and ORRA industrial receivers, place jumper
JP3
in the short-
circuit position (
JP1
and
JP2
not short-circuited ), for the ORRD receiver, set
microswitch
JP3
to the «ON» position.
)
)
)
)
)
In case of association programming error, the receiver memory can be
erased by following the procedure described in
§ 5.10
z
Transmitter and receiver have to be on the same operating radio channel.
Requirements:
REMARK :
each receiver relay can learn a maximum of :
- 10 different «button n identity codes» for DIN Rail receivers
(ORRD) and «small model» industrial receivers (ORRS)
- 4 different «button n identity codes» for the industrial «large
model» receivers (ORRA)
JP3
jumper
ORRS receiver
JP3
jumper
ORRA receiver
JP3
microswitch
ORRD receiver
3-
Follow the procedure described by the algorithm in following page.
Содержание OREi21SL1
Страница 2: ... 2 324501E revision02 ...
Страница 123: ...Gb De 324501E revision02 123 Fr Annexes Appendix Anhang ...
Страница 134: ... 134 324501E revision02 ...
Страница 136: ... 136 324501E revision02 ...
Страница 137: ...324501E revision02 137 NOTES ...
Страница 138: ... 138 324501E revision02 NOTES ...
Страница 139: ...324501E revision02 139 ...