2-6
LGG100 Operator’s Manual
www.javad.com
S E T U P A N D M E A S U R I N G
DGPS Measuring with the LGG100
2
Figure 2-4. Receiver Configuration – Positioning
10. Select the
Base
tab and set the following parameters (Figure 2-5 on
•
GPS/GLO at one time
- enable
•
Antenna position
- enter Lat, Lon, and Alt values. Do one of the
following:
–If known, type in the values.
–Click
Get from receiver
.
–Enable
Averaged
and enter the in seconds, then click
Apply
.
11. Click
Tools->Reset receiver
and wait until the specified interval (span)
completes. Examine the Base coordinates on the Base tab; they should
correspond to the coordinates obtained from the average.
12. Click
Refresh
if the coordinates are zeros.
Notice:
The reference geodetic coordinates you specify on this
tab relate to the antenna L1 phase center.