General
Pipe installation must be carried out in accordance with
current norms and directives.
The pipe dimension should not be less than the recom-
mended pipe diameter according to the table. However,
each system must be dimensioned individually to man-
age the recommended system flows.
Minimum system flows
The installation must be dimensioned to manage at least
the minimum defrosting flow at 100% pump operation,
see table.
Minimum
recommen-
ded pipe di-
mension
(mm)
Minimum
recommen-
ded pipe di-
mension
(DN)
Minimum
flow during
defrosting
(100%
pump
speed (l/s)
Air/water
heat pump
22
20
0.27
Inverter Nord-
ic-8 (1x230V)
JÄSPI Inverter
Nordic-8
28
25
0.35
Inverter Nord-
ic-12
(1x230V)
Inverter Nord-
ic-12
28
25
0.38
Inverter Nord-
ic-16
35
32
0.48
Inverter Nord-
ic-20
NOTE
An undersized system can result in damage to
the product and lead to malfunctions.
JÄSPI Inverter Nordic can only operate up to a return
temperature of about 55 °C and an outgoing temperat-
ure of about 65 °C from the heat pump.
JÄSPI Inverter Nordic is not equipped with shut-off valves
on the heating medium side, rather these must be in-
stalled to facilitate any future servicing. The return tem-
perature is limited by the return line sensor.
Water volumes
Depending on the size of your JÄSPI Inverter Nordic, an
available water volume is required to prevent short op-
erating times and to enable defrosting. For the optimum
operation of JÄSPI Inverter Nordic, a minimum available
water volume of 10 litres multiplied by the size number
is recommended. E.g. JÄSPI Inverter Nordic-12: 10 litres
x 12 = 120 litres. This applies individually to heating and
cooling systems.
NOTE
The pipe installation must be flushed out be-
fore the heat pump is connected so debris
cannot damage component parts.
Symbol key
Meaning
Symbol
Shut-off valve
Tapping valve
Non-return valve
Circulation pump
Expansion vessel
Filterball
Pressure gauge
P
Safety valve
Trim valve
Reversing valve/shunt
Control module
Air/water heat pump
Radiator system
Domestic hot water
Water heater
Pipe coupling heating medium
circuit
Connecting the climate system
Install as follows:
■
expansion vessel
■
pressure gauge
■
safety valves
■
drain valve
For draining the heat pump during prolonged power
failures.
■
non-return valve
Installations with only one heat pump: a non-return
valve is only required in those cases where the place-
ment of the products in relation to each other can
cause self-circulation.
Cascade installations: each heat pump must be fitted
with a non-return valve.
JÄSPI Inverter Nordic
Chapter 4 |
Pipe connections
20
4 Pipe connections