ELECTRICAL

Electrical Power Supply:  

These instructions are written 

assuming  60Hz,  120v  power  supply.    Special  notations 
are also included for export versions of the pump, control 
equipment, and power supply.

WARNING: Verification of electrical requirements MUST 

be made before installation. Refer to the equipment labels 

for voltage and frequency requirements.

NOTE: 

Verify that the electrical service matches either the 

120v or 240v system requirements for this bath.

NOTE:

 The bath is designed for indoor use only. The electri-

cal equipment must not be exposed to direct or indirect water 
or moisture contact. The electrical equipment must also be 
protected from dust and other airborne debris before, during, 
and after installation.

1. 

Electrical Service:

 A licensed electrician must provide 

the “dedicated” electrical service protected by a GFCI. 
The location of the GFCI must be at least five (5) feet (152 
cm) away from the inside surface of the bath, accessible 
for regular testing. Use copper conductors only.

DANGER  —  RISK  OF  ELECTRIC  SHOCK:

  Connect 

only to a circuit protected by a Ground Fault Circuit In-
terrupter (GFCI). In the unlikely occurrence of a current 
imbalance in the power conductors, the GFCI will interrupt 
the power to the bath.

WARNING:

 The electrical service to the GFCI must not be 

interrupted by any control device. Likewise, the electrical 

service from the GFCI to the bath control should be direct 
and not interrupted by a switch. Never use a switch in 
conjunction with a control device. 

This will VOID THE 

MANUFACTURER’S WARRANTY.

2. 

GROUNDING IS REQUIRED

The unit should be installed by a qualified service 

representative and properly grounded.

3. 

INSTALL SERVICE CONNECTION AT LEAST 6” (15cm) 

ABOVE SUB FLOOR.

ALL LOCAL AND STATE ELECTRICAL AND PLUMB-

ING CODES MUST BE OBSERVED

. Where there are no 

local codes the 

National Electric Code (NEC) and Uni-

form Plumbing Code (UPC)

 shall be observed. It is the 

responsibility of the installer/owner to determine specific 
code compliance prior to installation of the product.

NOTE:

  In  the  Commonwealth  of  Massachusetts,  in-

stallation  is  to  be  done  by  a  Massachusetts  licensed 
plumber.

4.

  Integrity  Whirlpool  Control  Box  (120v,60Hz): 

This 

Whirlpool  bath  is  provided  with  an  Air  On/Off  switch. 
The pump is pre-wired to a control box which has a 36” 
cord. Connect the pump to a GFCI (Ground Fault Circuit 
Interupter) with 120v (volt), 20A (amp), 60HZ (hertz) elec-
trical service with a service ground receptacle dedicated 
for use by this bath.

5.

  Export Integrity Whirlpool Control Box (240v,60Hz): 

This Whirlpool bath is provided with an Air On/Off switch. 
The pump is pre-wired to a control box which has a 36” 

INSTALLATION INSTRUCTIONS (cont.)

Figure 3

Содержание Integrity 3260 SR

Страница 1: ...y of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrep...

Страница 2: ...x 43 254 J4260 60 x 42 x 20 5 43 1 36 x 17 36 3 152 x 107 x 52 162 91 x 43 177 J4266 66 x 42 x 20 5 46 1 36 x 17 41 9 168 x 107 x 52 174 91 x 43 204 J4272 72 x 42 x 20 5 49 1 36 x 17 33 2 183 x 107 x...

Страница 3: ...the bath in the area of intended installation 4 Finishplumbingrough inofdrainandoverflowassembly At this time considerations should be made for the position and mounting of the faucet set as well as a...

Страница 4: ...FCIwillinterrupt the power to the bath WARNING TheelectricalservicetotheGFCImustnotbe interrupted by any control device Likewise the electrical service from the GFCI to the bath control should be dire...

Страница 5: ...ce for long periods of time Always rinse the surface immediately following the use of cleaners 3 Follow the manufacturer s instructions for safe use of cleaning products If the surface becomes scratch...

Страница 6: ...JETS Before starting the pump direct the jet nozzles downward to prevent the possibility of water splashing from the bath When bath is in use turn the unit Off before draining the water The bath unit...

Страница 7: ...RE WORK IS STARTED HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which may be harmful to health thrive in areas with continued high humidity levels therefore...

Страница 8: ...o the company within thirty 30 days from the occurrence thereof Written permission must be obtained by the retailer or distributor from the Company before any equipment claimed defective is returned f...

Страница 9: ...cs narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a hydrotherap...

Отзывы: