background image

 

29 

EC Declaration of Conformity 

 

The manufacturer, or its legal representative supplier in the European Community Jasic, declares that the 
equipment described below is designed and produced according to following EU - Directives: 
 
- Low Voltage Directive No: 2014/35/EU 
- EMC Directive No: 2014/30/EU with their amendments 
 
Inspected according to following EU - Norms: 
- EN 60 974-1 
- EN 60 974-10 
 
Type: Jasic Plasma Cut 61 (JP-61) 
           Jasic Plasma Cut 81 (JP-81) 
 
Any alteration or change to these machines by any unauthorized person makes this declaration invalid. 
 
 

WEEE disposal 

 

The equipment is manufactured with materials which do not contain any toxic or poisonous materials    
dangerous to the operator.  
When the equipment is scrapped, it should be dismantled separating components according to the type 
of materials. 
Do not dispose of the equipment with normal waste. The European Directive 2002/96/EC on Waste     
Electrical and Electronic Equipment states the electrical equipment that has reached its end of life must 
be collected separately and returned to an environmentally compatible recycling facility. 
Jasic has a relevant recycling system which is compliant and registered in the UK with the environment 
agency. Our registration reference is WEEMM3813AA. 
In order to comply with WEEE regulations outside the UK you should contact your supplier. 
 
 

RoHS Compliance Declaration 

 

We herewith confirm, that the above mentioned product does not contain any of the restricted            
substances as listed in EU Directive 2011/65/EC in concentrations above the limits as specified therein. 
 
Disclaimer: 
Please note that this confirmation is given to the best of our present knowledge and belief. 
Nothing herein represents and/or may be interpreted as warranty within the meaning of the applicable   
warranty law. 

Содержание Plasma Cut Series

Страница 1: ...Operator Manual Plasma Cut Series Plasma Cut 60 JP 61 Plasma Cut 80 JP 81...

Страница 2: ...nty purposes and to ensure you get the correct information should you require assistance or spare parts Date purchased ________________________________________ From where _____________________________...

Страница 3: ...claration 9 LF declaration 9 Materials and their disposal 9 Product Overview 10 Product details and application 11 Technical Specifications 12 Description of Controls 13 Remote Control Connection 15 I...

Страница 4: ...________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _...

Страница 5: ...and overheating Never use worn damaged under sized or poorly jointed cables Insulate yourself from work and earth using dry insulating mats or covers big enough to prevent any physical contact Never...

Страница 6: ...lty welding helmets Always ensure there are adequate protective screens or barriers to protect others from flash glare and sparks from the welding area Ensure that there are adequate warnings that wel...

Страница 7: ...he the welding fume Ensure the welding zone is well ventilated and provision should be made for suitable local fume extraction system to be in place If ventilation is poor wear an approved airfed weld...

Страница 8: ...ated by high currents may affect the operation of pacemakers or electronically controlled medical equipment Wearers of vital electronic equipment should consult their physician before beginning any ar...

Страница 9: ...y current from the power supply network high power systems affect the quality of power provided by the network Consequently connection restrictions or maximum impedance requirements permitted by the n...

Страница 10: ...ghtweight inverter plasma cutting machine High efficiency plasma which is ideal for cutting steel stainless copper cast iron and aluminium Convenient single carry handle easy to manoeuvre Non HF pilot...

Страница 11: ...as the plasma gas source The cutting speed is 1 8 times when compared with oxy acetylene cutting These machines can cut steel stainless steel copper cast iron and aluminium easily and quickly The arc...

Страница 12: ...60HZ Rated input power kVA 10 8 15 8 Rated input current Imax A 15 22 Rated input current Ieff A 9 5 14 Cutting current range A 20 60 20 80 Rated output voltage V 104 112 Rated duty cycle 60A 40 40 C...

Страница 13: ...current demand 6 2T 4T torch trigger latch selection switch A useful function when carrying out longer cuts when cutting in 4T mode you can remove your finger off the torch trigger and the arc will r...

Страница 14: ...cool down 4 A Current control dial this function allows the user to set the required current demand which is displayed on the digital ammeter 5 Pressure gauge which will display the preset pressure se...

Страница 15: ...t which is a normally open dry contact closure when the plasma arc transfers PRIOR TO A CNC INSTALLATION ALWAYS CHECK THE DIVIDED ARC SETTING TO ENSURE ITS CORRECTLY SET FOR YOUR INSTALLATION The foll...

Страница 16: ...equirements are as follows Minimum air input 5 Bar 73psi Minimum air flow 7 1CFM 200Ltr min Connect the compressed air with the supplied air hose and air fitting to the machine via the inlet connectio...

Страница 17: ...he open circuit voltage could be as high as 350V DC at the torch head The torch head encompasses a full set of consumables as shown right these consumables are made up of a cooling tube torch electrod...

Страница 18: ...tration The basic principle is that the arc is formed between the electrode and the work piece by forcing the plasma gas and the electrical arc through a small orifice within the copper tip This will...

Страница 19: ...ing Drag cutting is the process of dragging the tip of the torch along the work piece to cut the metal This is often the easiest way to cut while minimizing heat input but usually only on cutting curr...

Страница 20: ...for bevelling again you need to ensure you utilize the correct plasma machine amperage to match the cutting tips used Ensure that the thickness of the material to be bevelled falls in the amperage ra...

Страница 21: ...cutting systems use of a drag shield cup a standoff guide or a cutting guide will help keep a consistent tip to work distance for best results Kerf width While plasma cutting a void is left behind wh...

Страница 22: ...output cutting table quality material thickness along with material type being cut as well as the operators skill set Speeds shown below are offered as a guide only for our Jasic cutting systems usin...

Страница 23: ...ting the air flow The cutting torch may be burned if the air flow is too low Keep the cutting cable away from sharp edges 8 When the work piece is nearly cut off slow down the cutting speed and releas...

Страница 24: ...h the PT100 which has a current rating of 100amps this torch is supplied from new with the 100amp tip fitted When ordering replacement cutting tips please take note that the maximum sized tip that sho...

Страница 25: ...t dust out of the power supply Period Maintenance item Daily examination Check the condition of the machine mains cables welding cables and connections Check for any warnings LEDs and machine operatio...

Страница 26: ...nsure the plasma torch is fully fitted 5 Reconnect the machine to the mains supply and switch the machine back on still taking care not to touch any electrical parts within the machine 6 Switch on the...

Страница 27: ...cult to diagnose cutting issues without understanding the machines use and setup and there are various questions that need to be asked to be able to give the best advice Below is listed a few pointers...

Страница 28: ...torch along Excessive piloting Keeping the pilot arc maintained will erode the consumables much faster than when cutting keep piloting to a minimum Poor cut quality Improper travel speed Refer to the...

Страница 29: ...terials Do not dispose of the equipment with normal waste The European Directive 2002 96 EC on Waste Electrical and Electronic Equipment states the electrical equipment that has reached its end of lif...

Страница 30: ...e scope of the warranty Defects due to natural wear and tear Failure to observe the operating and maintenance instructions Connection to an incorrect or faulty mains supply Overloading during use Any...

Страница 31: ..._________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________...

Страница 32: ...www jasic co uk Wilkinson Star Limited Shield Drive Wardley Industrial Estate Worsley Manchester UK M28 2WD 44 0 161 793 8127 April 2020 Issue 3...

Отзывы: