background image

In-Wall

Smart

Switch

All brand names shown are trademarks of 

their respective owners
MADE IN CHINA
Distributed by Jasco Products Company LLC,                                              

10 E. Memorial Rd., Oklahoma City, OK 73114.
©JASCO 2020 | ZW4008 | 39348 | 09/03/20 v3

Z-Wave® certified 

wireless lighting control

39348

ZW4008

For deals, to register 

your purchase and to 

tell us how we’re 

doing, simply scan

the code or visit 

byjasco.com/deals

Instructions made easy 

Read instructions or 

watch easy-to-follow 

video. 

Scan code or visit

byjasco.com/39348i

Thank you

 for your purchase!

Like our product? 

Leave a review

on amazon.com

Having problems? 

Let us know how 

we can help. 

1-800-654-8483 

between 7AM-8PM, 

M-F, Central Time.

For additional UltraPro  

products, visit our website. 

www.ezzwave.com

WARRANTY

Jasco Products Company warrants this product to be free from manufacturing defects for five years 

from the original date of consumer purchase. This warranty is limited to the repair or replacement of 

this product only and does not extend to consequential or incidental damage to other products that 

may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. 

Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or 

limitation of incidental or consequential damage, so the above limitations may not apply to you. This 

warranty gives you specific rights and you may also have other rights which vary from state to state. 

Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F, 

Central Time or www.byjasco.com if the unit should prove defective within the warranty period.

2. INSTALLATION (CONT.)

2. INSTALLATION

1. FEATURES

SPECIFICATIONS -

 IMPORTANT!

ZW4008

Power: 120VAC, 60Hz

Signal (frequency): 908.4/916 MHz

Maximum loads: 960W incandescent, 1/2HP motor or 1800W (15A) resistive

Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module

Operating temperature range: 32-104° F (0-40° C)

Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action, 

pollution degree (2), rated impulse voltage (2500V), software class A

For indoor use only

Specifications subject to change without notice due to continuing product improvement

Z-WAVE INTEROPERABILITY

This product can be included and operated in any Z-Wave network with other Z-Wave certified 

devices from other manufacturers and/or other applications. All non-battery operated nodes within 

the network will act as repeaters regardless of vendor to increase reliability of the network.

WARNING

RISK OF FIRE

RISK OF ELECTRICAL SHOCK

RISK OF BURNS

CONTROLLING APPLIANCES 

CAUTION: 

•  DO NOT EXCEED RATINGS

•  DO NOT USE TO CONTROL  

  ANY DEVICE WHERE  

  UNINTENDED OPERATION  

  COULD CAUSE UNSAFE  

  CONDITIONS (HEAT LAMP,  

  SUN LAMP, ETC.)

•  DO NOT USE TO CONTROL  

 RECEPTACLES

•  FOR INDOOR USE ONLY

NOT FOR USE WITH MEDICAL 

OR LIFE-SUPPORT EQUIPMENT

Z-WAVE ENABLED DEVICES 

SHOULD NEVER BE USED TO 

SUPPLY POWER TO OR 

CONTROL THE ON/OFF STATUS 

OF MEDICAL AND 

LIFE-SUPPORT EQUIPMENT.

FCC/IC - EN

This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS 

standards. Operation is subject to the following two conditions: (1) this device may not 

cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.

FCC NOTE: 

The manufacturer is not responsible for any radio or TV interference caused 

by unauthorized modifications to this equipment. Such modifications could void the 

user’s authority to operate the equipment

NOTE: 

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy, and if not installed 

and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different to which the receiver is  

 connected.

• Consult the dealer or an experienced radio/TV technician for help.

IMPORTANT NOTE: 

To comply with the FCC RF exposure compliance requirements, no 

change to the antenna or the device is permitted. Any change to the antenna or the 

device could result in the device exceeding the RF exposure requirements and void user’s 

authority to operate the device. 

Responsible Party - US Contact Information

FCC — U2ZZW4008 | IC: 6924A-ZW4008

Jasco Products Company | Model: ZW4008/39348

10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483

CAN ICES-3(B)/NMB-3(B)

CHANGING THE COLOR OF THE PADDLE
NOTE:

 

Additional colors available on 

www.byjasco.com.

1.  Lift the air gap tab at the base of the  

 paddle.
2.  Push side tabs in on one side and  

 

then the other to release paddle. Lift  

 

the cover up and off.

3.  Simply put the new paddle onto the  

 

switch by inserting the air gap and  

 

side tabs and snapping securely into place.

•  May be used in single-pole installation or with up to four add-on switches    

  (model 39350) in 3-way or 4-way wiring configurations

•  Auto line/load detection

• Blue LED indicates switch location in a dark room

•  Screw terminal installation — requires wiring connections for line (hot), load,  

  neutral and ground. Traveler wire required for 3-way or 4-way installation

•  This Z-Wave device has advanced features that allow you to customize  

 

  your experience. For a complete list of adjustable configurations, visit  

 

 www.ezzwave.com

3. CONNECTION

3. CONNECTION (CONT.)

OPTIONAL CUSTOMIZATION

A.

  Ground (Green/Bare)

B.

  Line or Load (Black)

C.

  Line or Load (Black)

D.

  Traveler (Red/Other)

E.

  Neutral (White)

F.

  Top rocker — press  

 

to turn switch ON

G.

  Bottom rocker —  

 

press to turn  

 

switch OFF

A

B

C

D

E

F

G

This device supports Association Command Class (3 Groups)
•  Association Group 1 supports Lifeline, Binary Switch Report
•  Association Group 2 supports Basic Set and is controlled by pressing  

  the ON or OFF button with the local load
•  Association Group 3 supports Basic Set and is controlled by double  

  pressing the ON or OFF button
•  Each Association Group supports 5 total nodes

1

2

WARNING — SHOCK HAZARD

Turn OFF the power to the branch circuit for the switch and lighting fixture at the 

service panel. All wiring connections must be made with the POWER OFF to 

avoid personal injury and/or damage to the switch. This device is intended for 

installation in accordance with the National Electric Code and local regulations in 

the United States, or the Canadian Electrical Code and local regulations in 

Canada. If you are unsure or uncomfortable about performing this installation, 

consult a qualified electrician.

REMOVING AND RESETTING THE DEVICE

1.  Follow the instructions for your Z-Wave certified controller to remove a    

 

device from the Z-Wave network. 

2.  Once the controller is ready to remove your device, press and release the top   

 

or bottom of the smart switch (rocker).

RETURNING SWITCH TO FACTORY DEFAULTS

Quickly press ON (top) button three times, then, immediately press the OFF 

(bottom) button three times. The LED will flash ON/OFF five times when 

completed successfully.

NOTE: 

This should only be used in the event your network’s primary controller is 

missing or otherwise inoperable.

NOTE: 

SmartStart enabled products can be added into a Z-Wave network by 

scanning the QR code on the product with a controller providing SmartStart 

inclusion. No further action is required and the SmartStart product will be added 

automatically within 10 minutes of being switched on in the network vicinity.

Z-WAVE  DSK

PIN:  XXXXX

DSK  :   

XXXXX

 

-25651-22671

 

-26939-47599

 

-19612-25872

 

-47752

MULTI-SWITCH WIRING

Add-on switch model 39350 is required for 

multi-switch installations. For more information 

on multi-switch installations, refer to the add-on 

switch manual.

SINGLE-SWITCH WIRING 

1.  Shut off power to the circuit at circuit breaker  

  or fuse box.

IMPORTANT! 

Verify power is OFF to switch box 

before continuing.
2. Remove wallplate.
3. Remove the switch  mounting screws.

4.  Carefully remove the switch  

 

from the switch box. DO  

 

NOT disconnect the wires.

5.  There are up to five screw  

 

terminals on the switch;   

 

these are marked: 

 

A. GROUND — Green/Bare 

 

B.  LINE OR LOAD — Black  

 

  (connected to power or  

   lighting)
 

C.  LINE OR LOAD — Black  

 

  (connected to power or  

   lighting)
 

D. TRAVELER —  

 

 

  Red/Other (only in    

 

  3-way installations)

 

E.  NEUTRAL — White

Match these screw terminals  

to the wires connected to the  

existing switch.

6.  Disconnect the wires from the existing switch. Label wires according to the  

 

previous terminal connection.

OBSERVE IMPORTANT WIRING INFORMATION
IMPORTANT!

 This switch is rated for and intended to only be used with copper wire.

WIRE GAUGE REQUIREMENTS

Use 14AWG or larger wires suitable for at least 80° C for supplying line (hot), 

load, neutral, ground and traveler connections.
UL specifies the tightening torque for the 

screws is 14Kgf-cm (12lbf-in)

WIRE STRIP LENGTH

7.  For attachment using the enclosure’s holes,  

 

strip insulation 5/8in. (16mm).

8.  Connect the green or bare copper ground  

 

wire to the GROUND terminal (A).

9.  Connect the black wire from the light to    

 

either LINE/LOAD terminal (B).

10.  Connect the black wire from the electrical   

 

service panel (hot) to the other  

 

 

LINE/LOAD terminal (C).

11.  Connect the white wire to the neutral  

 

 

terminal (E) (use a jumper wire if needed).

7

12.  Insert switch into the switch box being careful not to pinch or crush wires.
13.  Switch must be independently mounted (vertical position only).
14.  Secure the switch to the box using the supplied screws.
15.  Mount the wallplate.

16.  Reapply power to the circuit at fuse box or circuit breaker and test the system.

MANUAL CONTROL

The front panel rocker switch allows the user to turn ON/OFF the connected fixture.
1.  To turn the connected fixture ON, press and release the top of the rocker.
2.  To turn the connected fixture OFF, press and release the bottom of the rocker.

CYCLE LED LIGHT

The LED below the switch acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.
1.  LED is ON when the load is OFF (guide light in the dark) (default).
2.  LED is ON when the load is ON (indicates the switch is ON).
3.  LED is always OFF.
4.  LED is always ON (illuminates switch in the dark).

OUT TO 

LIGHT (LOAD)

FROM 

BREAKER BOX

Insert wires into holes, do not wrap

wires around screws.
Do not remove screws.

B

A

E

C

1

2

3

 

OUT TO 

LIGHT (LOAD)

FROM 

BREAKER BOX

B

A

E

C

8 9 10 11

CONNECTING TO A Z-WAVE NETWORK

1.  Follow the instructions for your Z-Wave  

 

certified controller to add a device to the  

 

Z-Wave network.

2.  Once the controller is ready to add your  

 

device, press and release the top or  

 

bottom of the smart switch (rocker).

If prompted by the controller to enter the S2 

security code, refer to the QR code/security 

number on the back of the box or the QR 

code label on the product.

2. INSTALLATION (CONT.)

2. INSTALLATION (CONT.)

14

15

Содержание ZW4008

Страница 1: ...s shown are trademarks of their respective owners MADE IN CHINA Distributed by Jasco Products Company LLC 10 E Memorial Rd Oklahoma City OK 73114 JASCO 2020 ZW4008 39348 09 03 20 v3 Z Wave certified wireless lighting control 39348 ZW4008 ...

Страница 2: ... made easy Read instructions or watch easy to follow video Scan code or visit byjasco com 39348i Thank you for your purchase Like our product Leave a review on amazon com Having problems Let us know how we can help 1 800 654 8483 between 7AM 8PM M F Central Time For additional UltraPro products visit our website www ezzwave com ...

Страница 3: ...zwave com A Ground Green Bare B Line or Load Black C Line or Load Black D Traveler Red Other E Neutral White F Top rocker press to turn switch ON G Bottom rocker press to turn switch OFF A B C D E F G WARNING SHOCK HAZARD Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel All wiring connections must be made with the POWER OFF to avoid personal injury ...

Страница 4: ...re continuing 2 Remove wallplate 3 Remove the switch mounting screws 4 Carefully remove the switch from the switch box DO NOT disconnect the wires 5 There are up to five screw terminals on the switch these are marked A GROUND Green Bare B LINE OR LOAD Black connected to power or lighting C LINE OR LOAD Black connected to power or lighting D TRAVELER Red Other only in 3 way installations E NEUTRAL ...

Страница 5: ...ue for the screws is 14Kgf cm 12lbf in WIRE STRIP LENGTH 7 For attachment using the enclosure s holes strip insulation 5 8in 16mm 8 Connect the green or bare copper ground wire to the GROUND terminal A 9 Connect the black wire from the light to either LINE LOAD terminal B 10 Connect the black wire from the electrical service panel hot to the other LINE LOAD terminal C 11 Connect the white wire to ...

Страница 6: ...d release the bottom of the rocker CYCLE LED LIGHT The LED below the switch acts as a guide light or status indicator How to cycle through options Press up three times and down once quickly 1 LED is ON when the load is OFF guide light in the dark default 2 LED is ON when the load is ON indicates the switch is ON 3 LED is always OFF 4 LED is always ON illuminates switch in the dark CONNECTING TO A ...

Страница 7: ...Association Group supports 5 total nodes 1 2 REMOVING AND RESETTING THE DEVICE 1 Follow the instructions for your Z Wave certified controller to remove a device from the Z Wave network 2 Once the controller is ready to remove your device press and release the top or bottom of the smart switch rocker RETURNING SWITCH TO FACTORY DEFAULTS Quickly press ON top button three times then immediately press...

Страница 8: ...DOOR USE ONLY NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT Z WAVE ENABLED DEVICES SHOULD NEVER BE USED TO SUPPLY POWER TO OR CONTROL THE ON OFF STATUS OF MEDICAL AND LIFE SUPPORT EQUIPMENT FCC IC EN This device complies with Part 15 of the FCC and Industry Canada license exempt RSS standards Operation is subject to the following two conditions 1 this device may not cause harmful interference...

Отзывы: