In-Wall
Smart
Switch
All brand names shown are trademarks of
their respective owners
MADE IN CHINA
Distributed by Jasco Products Company LLC,
10 E. Memorial Rd., Oklahoma City, OK 73114.
©JASCO 2020 | ZW4008 | 39348 | 09/03/20 v3
Z-Wave® certified
wireless lighting control
39348
ZW4008
For deals, to register
your purchase and to
tell us how we’re
doing, simply scan
the code or visit
byjasco.com/deals
Instructions made easy
Read instructions or
watch easy-to-follow
video.
Scan code or visit
byjasco.com/39348i
Thank you
for your purchase!
Like our product?
Leave a review
on amazon.com
Having problems?
Let us know how
we can help.
1-800-654-8483
between 7AM-8PM,
M-F, Central Time.
For additional UltraPro
products, visit our website.
www.ezzwave.com
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for five years
from the original date of consumer purchase. This warranty is limited to the repair or replacement of
this product only and does not extend to consequential or incidental damage to other products that
may be used with this product. This warranty is in lieu of all other warranties, expressed or implied.
Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or
limitation of incidental or consequential damage, so the above limitations may not apply to you. This
warranty gives you specific rights and you may also have other rights which vary from state to state.
Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F,
Central Time or www.byjasco.com if the unit should prove defective within the warranty period.
2. INSTALLATION (CONT.)
2. INSTALLATION
1. FEATURES
SPECIFICATIONS -
IMPORTANT!
ZW4008
Power: 120VAC, 60Hz
Signal (frequency): 908.4/916 MHz
Maximum loads: 960W incandescent, 1/2HP motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
Operating temperature range: 32-104° F (0-40° C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action,
pollution degree (2), rated impulse voltage (2500V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other applications. All non-battery operated nodes within
the network will act as repeaters regardless of vendor to increase reliability of the network.
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES
CAUTION:
• DO NOT EXCEED RATINGS
• DO NOT USE TO CONTROL
ANY DEVICE WHERE
UNINTENDED OPERATION
COULD CAUSE UNSAFE
CONDITIONS (HEAT LAMP,
SUN LAMP, ETC.)
• DO NOT USE TO CONTROL
RECEPTACLES
• FOR INDOOR USE ONLY
NOT FOR USE WITH MEDICAL
OR LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES
SHOULD NEVER BE USED TO
SUPPLY POWER TO OR
CONTROL THE ON/OFF STATUS
OF MEDICAL AND
LIFE-SUPPORT EQUIPMENT.
FCC/IC - EN
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS
standards. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC NOTE:
The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. Such modifications could void the
user’s authority to operate the equipment
NOTE:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT NOTE:
To comply with the FCC RF exposure compliance requirements, no
change to the antenna or the device is permitted. Any change to the antenna or the
device could result in the device exceeding the RF exposure requirements and void user’s
authority to operate the device.
Responsible Party - US Contact Information
FCC — U2ZZW4008 | IC: 6924A-ZW4008
Jasco Products Company | Model: ZW4008/39348
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
CHANGING THE COLOR OF THE PADDLE
NOTE:
Additional colors available on
www.byjasco.com.
1. Lift the air gap tab at the base of the
paddle.
2. Push side tabs in on one side and
then the other to release paddle. Lift
the cover up and off.
3. Simply put the new paddle onto the
switch by inserting the air gap and
side tabs and snapping securely into place.
• May be used in single-pole installation or with up to four add-on switches
(model 39350) in 3-way or 4-way wiring configurations
• Auto line/load detection
• Blue LED indicates switch location in a dark room
• Screw terminal installation — requires wiring connections for line (hot), load,
neutral and ground. Traveler wire required for 3-way or 4-way installation
• This Z-Wave device has advanced features that allow you to customize
your experience. For a complete list of adjustable configurations, visit
www.ezzwave.com
3. CONNECTION
3. CONNECTION (CONT.)
OPTIONAL CUSTOMIZATION
A.
Ground (Green/Bare)
B.
Line or Load (Black)
C.
Line or Load (Black)
D.
Traveler (Red/Other)
E.
Neutral (White)
F.
Top rocker — press
to turn switch ON
G.
Bottom rocker —
press to turn
switch OFF
A
B
C
D
E
F
G
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled by pressing
the ON or OFF button with the local load
• Association Group 3 supports Basic Set and is controlled by double
pressing the ON or OFF button
• Each Association Group supports 5 total nodes
1
2
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the
service panel. All wiring connections must be made with the POWER OFF to
avoid personal injury and/or damage to the switch. This device is intended for
installation in accordance with the National Electric Code and local regulations in
the United States, or the Canadian Electrical Code and local regulations in
Canada. If you are unsure or uncomfortable about performing this installation,
consult a qualified electrician.
REMOVING AND RESETTING THE DEVICE
1. Follow the instructions for your Z-Wave certified controller to remove a
device from the Z-Wave network.
2. Once the controller is ready to remove your device, press and release the top
or bottom of the smart switch (rocker).
RETURNING SWITCH TO FACTORY DEFAULTS
Quickly press ON (top) button three times, then, immediately press the OFF
(bottom) button three times. The LED will flash ON/OFF five times when
completed successfully.
NOTE:
This should only be used in the event your network’s primary controller is
missing or otherwise inoperable.
NOTE:
SmartStart enabled products can be added into a Z-Wave network by
scanning the QR code on the product with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product will be added
automatically within 10 minutes of being switched on in the network vicinity.
Z-WAVE DSK
PIN: XXXXX
DSK :
XXXXX
-25651-22671
-26939-47599
-19612-25872
-47752
MULTI-SWITCH WIRING
Add-on switch model 39350 is required for
multi-switch installations. For more information
on multi-switch installations, refer to the add-on
switch manual.
SINGLE-SWITCH WIRING
1. Shut off power to the circuit at circuit breaker
or fuse box.
IMPORTANT!
Verify power is OFF to switch box
before continuing.
2. Remove wallplate.
3. Remove the switch mounting screws.
4. Carefully remove the switch
from the switch box. DO
NOT disconnect the wires.
5. There are up to five screw
terminals on the switch;
these are marked:
A. GROUND — Green/Bare
B. LINE OR LOAD — Black
(connected to power or
lighting)
C. LINE OR LOAD — Black
(connected to power or
lighting)
D. TRAVELER —
Red/Other (only in
3-way installations)
E. NEUTRAL — White
Match these screw terminals
to the wires connected to the
existing switch.
6. Disconnect the wires from the existing switch. Label wires according to the
previous terminal connection.
OBSERVE IMPORTANT WIRING INFORMATION
IMPORTANT!
This switch is rated for and intended to only be used with copper wire.
WIRE GAUGE REQUIREMENTS
Use 14AWG or larger wires suitable for at least 80° C for supplying line (hot),
load, neutral, ground and traveler connections.
UL specifies the tightening torque for the
screws is 14Kgf-cm (12lbf-in)
WIRE STRIP LENGTH
7. For attachment using the enclosure’s holes,
strip insulation 5/8in. (16mm).
8. Connect the green or bare copper ground
wire to the GROUND terminal (A).
9. Connect the black wire from the light to
either LINE/LOAD terminal (B).
10. Connect the black wire from the electrical
service panel (hot) to the other
LINE/LOAD terminal (C).
11. Connect the white wire to the neutral
terminal (E) (use a jumper wire if needed).
7
12. Insert switch into the switch box being careful not to pinch or crush wires.
13. Switch must be independently mounted (vertical position only).
14. Secure the switch to the box using the supplied screws.
15. Mount the wallplate.
16. Reapply power to the circuit at fuse box or circuit breaker and test the system.
MANUAL CONTROL
The front panel rocker switch allows the user to turn ON/OFF the connected fixture.
1. To turn the connected fixture ON, press and release the top of the rocker.
2. To turn the connected fixture OFF, press and release the bottom of the rocker.
CYCLE LED LIGHT
The LED below the switch acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.
1. LED is ON when the load is OFF (guide light in the dark) (default).
2. LED is ON when the load is ON (indicates the switch is ON).
3. LED is always OFF.
4. LED is always ON (illuminates switch in the dark).
OUT TO
LIGHT (LOAD)
FROM
BREAKER BOX
Insert wires into holes, do not wrap
wires around screws.
Do not remove screws.
B
A
E
C
1
2
3
OUT TO
LIGHT (LOAD)
FROM
BREAKER BOX
B
A
E
C
8 9 10 11
CONNECTING TO A Z-WAVE NETWORK
1. Follow the instructions for your Z-Wave
certified controller to add a device to the
Z-Wave network.
2. Once the controller is ready to add your
device, press and release the top or
bottom of the smart switch (rocker).
If prompted by the controller to enter the S2
security code, refer to the QR code/security
number on the back of the box or the QR
code label on the product.
2. INSTALLATION (CONT.)
2. INSTALLATION (CONT.)
14