Instruction Manual T601
JAQUET AG
Revision: 004
49/73
7.7.18 Data-logger Memory
This function is available since version 0.99.
To configure the data-logger go to <Configuration>, <Memory>.
The memory may be organised as: Ring buffer or limited memory.
Memory mode:
Ring buffer
/ Limited memory
Ring buffer: earlier data is over-written after a given number of
values.
Limited memory: a given number of values are stored. Once that
value is reached no further data is saved.
7.8 Settings
7.8.1 Ethernet Interface
Go to <Settings>, <Interface …>.
No settings can be made. The PC-T601 connection is peer to peer
(PC to PC). T601’s cannot be connected to a network!
For technical data see chapter 3.6.1 Ethernet.
DHCP Server
ON
/ OFF
TCP/IP Address
192.168.1.127
TCP/IP Mask
255.255.255.0