![Jaquet MultiTasker T601 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/jaquet/multitasker-t601/multitasker-t601_instruction-manual_3370759044.webp)
Instruction Manual T601
JAQUET AG
Revision: 004
44/73
Inversion
Every input may be inverted. Just select your event that triggers your
system limit.
Logical combination
The box must be ticked to include the input in the logical
combination.
Sensor Alarm
To OR Sensor alarm with the System Limit result the box must be
ticked.
7.7.13 Relay Outputs
To configure relay outputs go to <Configuration>, <Relay / Open
Collector>.
Relay configuration consists of:
Assignment, the latch function and the fail safe/not fail safe mode.
Latch Function:
Latched /
not latched
Safety function:
Fail safe
/ Not fail safe
System limit 1
Sensor alarm
System limit 2
Static S1
System limit 3
Static S2
System limit 4
Dynamic error
System limit 5
Always ON
System limit 6
Always OFF
Static Ain