FJ200 -CT USER`S MANUAL
V3.0
Page 16
Normal setting for circulation pump is
“AUTO”.
Duration time
setting is factory made
“Recipe”
. That means when milk reaches
setpoint temperature, it then holds at this
temperature for a set amount of time,
before it proceedes to the next phase.
If duration time is set as
“Manual”
, device
will hold at setpoint temperature for infinite
amount of time. Only with pressing the
key it switches to next phase.
Detailed menu
The detailed menu is entered when up key
is pressed in main menu configuration.
In first page of detailed menu on the left
side:
-
Milk temperature is shown
-
Secondary water temperature is
shown
-
Return water temperature is shown
-
Pressure state of secondary water is
displayed
-
Input sensor states are displayed in
binary form
-
Output sensor states are displayed in
binary form
Input sensors in binary form:
Digit 1- level sensor
Digit 2-
Digit 3-
Digit 4-
Digit 5-
Output sensors in binary form:
Digit 1- Heater 1
Digit 2- Heater 2
Digit 3- Circulation pump
Digit 4- Cooling solenoid valve
Digit 5- Mixing valve open (external source)