background image

Page 22

WATERPIK TECHNOLOGIES INC.

Key

     Model   ORDER

No        Description

    No

 PART NO

PILOT/IGNITER SYSTEM

1

Pilot, Main Burner Assembly,  NAT

All

R0099100

1

Pilot, Main Burner Assemby, 

 

LPG

All

R0099200

2

Pilot Burner,  NAT

All

R0096700

2

Pilot Burner,   LPG

All

R0096600

3

Pilot Electrode

All

W0040000

4

Pilot Generator

All

W0036901

5

Ceramic Insulator Assembly

All

10418820

6

Burner, Main w/Pilot Bracket

All

10457500

7

High Voltage Lead Assembly

All

R0099000

8

Pilot Tubing

All

R0037000

9

Piezo Lighter Assembly

All

R0096800

10

Pilot Condensate Shield - 

LG

All

R0323300

11

Ignitor - 

LD

All

R0317200

MAIN GAS ASSEMBLY

12

Burner Tray Assy,  NAT  - 

LG

125-400 R0098601-05

12

Burner Tray Assy,  LPG  -

 LG

125-400 R0098701-05

12

Burner Tray Assy,  NAT  - 

LD

125-400 R0316901-05

12

Burner Tray Assy,  LPG  - 

LD

125-400 R0319501-05

13

Burner Tray, Shelf Only

125-400 R0317001-05

14

Gas Valve,  NAT -

 LG

All

R0096400

14

Gas Valve,  LPG -

 LG

All

R0096900

14

Gas Valve,  NAT - 

LD

All

R0317100

14

Gas Valve,  LPG - 

LD

All

R0319600

15

Gas Orifice, NAT 0 - 3,000 ft alt. (EA.) 

(Note 1)

All

L0032200

15

Gas Orifice, LPG 0 - 5,000 ft alt. (EA.) 

(Note 2)

All

L0032900

16

Anti-Rotation Bracket

All

10835900

17

Mounting Bracket Assembly - 

LG

All

10419200

18

Burner, Main

All

L0052300

19

Burner Manifold

125

L0052200

19

Burner Manifold

175

L0006300

19

Burner Manifold

250

L0006400

19

Burner Manifold

325

L0006500

19

Burner Manifold

400

L0006600

ELECTRICAL SYSTEM

20

Temperature Control Assembly - 

LG

All

R0058200

21

Wire Harness

All

R0058000

22

Plate Assembly

All

10457300

23

On-Off Switch

All

R0099800

24

Temperature Control Label

All

H0105300

25

Temperature Control Assembly

 - LD

All

R0011700

26

Wire Harness Assembly

All

10457800

27

Plate Assembly

All

10594600

28

Knob, Single Bar

All

R0099900

29

Temperature Control Label

All

H0166500

Key Nos. 30- 37  are for both R582 (LG) & R117 (LD)

30

Temperature Sensor

All

R0011800

31

Protector Sleeve, Bulb

All

10444900

32

"O" Ring, Temperature Control Bulb

All

E0116400

33

Thermostat Knob, Black

All

R0010700

34

Stop Plate, "Temp-Lok"

All

10583100

35

Temperature Control Gasket

All

S0070000

36

Bezel

All

S0069800

37

Stop Plate Screw (Not Shown)

All

F0033300

38

Temperature Sensor Retainer Bracket

All

10447300

39

Retainer Bracket Screw

All

F0009100

40

Pressure Switch & Siphon Loop Assembly (2 PSI) All

R0097600

41

Pressure Switch, 2 PSI

All

R0013200

41

Pressure Switch, 1 PSI

All

R0011300

41

Pressure Switch, 1-10 PSI

All

R0015500

42

Siphon Loop Assembly

All

R0057800

43

High-Limit Switch Assembly

All

R0023200

44

High-Limit Switch,  135° F

All

R0022700

45

High-Limit Switch,  150° F

All

R0023000

46

High-Limit Switch Retainer Boot

All

S0098900

47

High-Limit Switch Wire Harness

All

10419300

48

High-Limit Switch Retainer Clip

All

10418400

49

High-Limit Switch Cover

All

10418300

50

Fusible Link Assembly

All

R0012200

51

Fusible Link Bracket

All

10479900

52

Terminal Block

All

R0097800

53

Ignition Control Assembly - 

LD

All

R0344600

54

Ignition Control  - 

LD

All

R0344500

55

Harness Assembly (Not Shown)

All

R0059800

56

Transformer (115V/220V-24V) (Not Shown)

All

R0061100

57

Ignition Control Panel (Not Shown)

All

10451200

58

In-Line Fuse Assembly (Not Shown)

All

10480000

VENT SYSTEM

59

Top Enclosure

125-400 R0343401-05

60

Top Filler Plate (US Only)

125-400 R0343701-05

61

Rainshield Kit (US Only)

125-400 R0318301-05

61

Rainshield Kit (Canada Only)

125-400 R0318311-15

62

Flue Collector Assembly (US Only)

125-400 R0316401-05

62

Flue Collector Assembly (Canada Only)

125-400 R0316406-10

63

Outdoor Vent Cap (US Only)

125-400 10561501-05

63

Outdoor Vent Cap (Canada Only)

125-400 10561511-15

64

Indoor  Drafthood  (US Only)

125-400 10561401-05

64

Indoor  Drafthood (Canada Only)

125-400 10561411-15

65

    Flue Transition Plate  (US Only)

125-400 10861901-05

66

    Adapter Plate

125-400 10535301-05

67

    Clip

All

10211000

68

Flue Collector Hold Down Clamp

All

10726000

WATER SYSTEM

69

Inlet/Outlet Header,  2"

All

R0056400

69

Inlet/Outlet Header, Bronze, 2"

All

R0016800

70

Return Header (Includes set of 9 gaskets)

All

R0058300

70

ReturnHeader, Bronze (Includes set of 9 gaskets) All

R0054600

71

Header Bolt Assembly (Set of 8)

All

R0057000

72

Bolt for Headers, 2 1/2"

All

F0046100

73

Washer for Headers

All

F0011100

74

Nut for Headers

All

F0003100

75

Header Gasket Assembly  (Set of 18)

All

R0050800

76

Flange & Gasket Assembly  (Set of 2 )

All

R0055000

77

Flange, 2"

All

10573500

78

Flange Gasket, 2"

All

S0078000

79

Flange Sleeve, 2"

All

S0078200

80

Flange Bolt

All

F0031700

81

Flange Gasket, 1 1/2 - 2"

All

S0078100

82

Rubber Grommet for Drain Plug

All

R0316300

83

Grommet, Slitted (Not Shown)

All

S0071100

84

Brass Connector Body

All

P0019701

85

Brass Drain Plug 1/4"

All

P0026800

86

Brass Plug, 3/4"

All

P0027000

87

By-Pass Assembly w/o spring (Iron Cap)

All

R0013100

87

By-Pass Assembly with spring (Bronze Cap)

125-400 10701401-05

88

By-Pass Valve Rod

All

S0079800

89

Brass Nut (For Rod)

All

F0048400

90

By-Pass Valve Disc

All

R0011500

91

By-Pass Valve Control Cap (Iron)

All

10452200

91

By-Pass Valve Control Cap  (Bronze)

All

10557400

92

Control Cap Bolts (2 Required)

All

F0041600

93

By-Pass Valve Spring, Purple

125

S0079900

93

By-Pass Valve Spring, White

175

S0061400

93

By-Pass Valve Spring, Red

250

S0061300

93

By-Pass Valve Spring, Blue

325

S0061200

93

By-Pass Valve Spring, Black

400

S0070100

94

By-Pass Valve Gasket

All

R0011400

95

Heat Exch. Tube Assy. (Incl. set of 18 gaskets)

125-400 R0018101-05

96

Heat Exchanger Baffle  (8 Required)

125-400 10697401-05

97

Baffle Retainer

All

S0083900

98

Heat Exchanger Support Clip (2 Required)

All

10457000

99

Flow Restrictors (2 Required) (Not Shown)

125

S0000300

100 Heat Exchanger End Baffles (2 Required)

125-400 R0332301-05

FIREBOX COMPONENTS

101 Complete Combustion Chamber Assy.125-400 R0316701-05

JACKET COMPONENTS

102 Door with Latch

125-400 R0343601-05

103 Jacket Assembly,  Less Top Assembly

125-400 R0343501-05

104 Gap Closure, Inlet/Outlet

All

R0344300

105 Gap Closure, Return

All

R0344400

106 Button Plug, 1-3/4"

All

F0035300

107 Button Plug, 7/8"

All

F0032300

108 Button Plug, 2" (With hole for gas line)

All

F0056600

OPTIONAL COMPONENTS

Non Combustible Base

125-400 10521701-05

Pressure Relief Valve 3/4" NPT, 75 PSI

All

R0040400

Touch Up Spray Paint, Light Beige

All

X0021100

Flame Sense Rod, Retrofit

All

R0334300

Igniter Condensate Shield, Retrofit - 

LD

All

R0334200

Notes:

1.  For altitudes 2,000 Ft above sea level, call factory for orifice size.

2.  For altitudes 5,000 Ft above sea level, call factory for orifice size.

Key

        Model       ORDER

No        Description

        No

      PART NO

Содержание Laars Lite 2 LD

Страница 1: ...y damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any...

Страница 2: ...9 2G 2 Reversible Water Connections 10 2G 3 Valve Installation 12 2G 4 Chlorinators Ozone Generators and Sanitizing Chemicals 12 2G4a Water Chemistry 13 2G 5 Pressure Relief Valve 13 2G 6 Adjusting t...

Страница 3: ...g with the latest edition of the Standard for Notes 1 In Canada derate BTU Hr input and output 10 percent for altitudes of 2 000 to 4 500 feet 609 to 1372 m above sea level No derating necessary up to...

Страница 4: ...the proper perfor mance and application of Waterpik Laars products For technical support call 415 382 8220 extension 260 SECTION 2 Installation Instructions 2A General Information Install the Laars L...

Страница 5: ...ate leakage If this is not possible provide a suitable drain pan to catch and divert any leakage The pan must not block natural flow of air around the heater Locate the heater so the clearances from c...

Страница 6: ...r at least 3 Figure 4 Non Combustible Platform Notes 1 Blocks must provide solid base and be braced so they cannot slip out of place 2 Air openings in blocks must be arranged to provide unrestricted o...

Страница 7: ...2 Check the rating plate to make sure the heater is fitted for the type of gas being used Waterpik Laars heaters as shipped from the factory are certified to operate at an altitude of 0 to 3000 feet 0...

Страница 8: ...ttention Au moment de l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux 2F 1 General Informatio...

Страница 9: ...gram b Schematic Diagram WIRING SHOWN AS SHALL USE APPLIANCE WIRING MATERIAL RATED AT 200 C O HSI IGNITION WIRE FACTORY WIRED 120 V 240 V FIELD WIRED 120V 240V FACTORY WIRED 24 V IF ORIGINAL WIRE SUPP...

Страница 10: ...de power to the heater from the high voltage side of the time clock Doing so may cause damage to the heater or surrounding plumbing 0 92 7 7 5 5 1 5 0 Y Connection Diagram BK TH PP Y Y W PP TH Pilot G...

Страница 11: ...connected by removing the jumper wire on the terminal block located in the control compartment see Figure 6 and connecting the two wires from the remote to the two terminals on the terminal block This...

Страница 12: ...side It could be necessary or helpful to switch the connections to the left side to improve access for installation and service Perform this modification before installing the heater using the follow...

Страница 13: ...changer 10 Unscrew the brass compression fitting securing the pressure switch to the inlet outlet header Remove tube from header and gently bend it out of the way 11 Loosenthescrewsecuringthetemperatu...

Страница 14: ...ater damage caused by exces sive chemicals or improper ozonization is not covered by the Waterpik Laars warranty Be sure to adhere to thefollowing When ozone is injected upstream of the heater install...

Страница 15: ...The back pressure could be too low to trigger the pressure switch If this happens it may be necessary to install a directional fitting or elbows where the return line enters the pool This will increas...

Страница 16: ...ains off This allows water from the pool to reach the heater 7 Record the temperature indicated by the ther mometer cold water 8 Turn the heater ON following the lighting in structions found on the in...

Страница 17: ...ve thermometer and Pete s plug d Replace the drain plug 2G 9 Adjusting the Manual Bypass Valve After the manual bypass valve is installed use the following procedures to adjust the bypass valve 1 Clea...

Страница 18: ...ts off the top of the heater Blocking air flow could damage the heater and may void the warranty WARNING Vent pipes drafthoods and heater tops get hot These surfaces can cause serious burns Do not tou...

Страница 19: ...to the appliance if service is to be performed 3 Turn gas control knob clockwise to OFF 4 Replace control access panel A This appliance does not have a pilot light It is equipped with an ignition dev...

Страница 20: ...he knob will not push in or turn by hand don t try to repair it Call a qualified service techni cian Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part...

Страница 21: ...only going to be used occasionally turn the temperature control down to the MIN setting This prevents the pool from water from becoming chilled and minimizes the time re quired to raise the pool wate...

Страница 22: ...temperature of 98 6 F 37 C Symptoms include dizziness fainting drowsiness lethargy and an increase in the internal body temperature The effects of hyperthermia include Lack of awareness of impending h...

Страница 23: ...ose or broken wires and terminal connections 2 Verify pressure switch operation by cycling the spa pump on and off a few times The heater should go off immediately after the pump stops 3 Inspect the e...

Страница 24: ...own All 10480000 VENT SYSTEM 59 Top Enclosure 125 400 R0343401 05 60 Top Filler Plate US Only 125 400 R0343701 05 61 Rainshield Kit US Only 125 400 R0318301 05 61 Rainshield Kit Canada Only 125 400 R0...

Страница 25: ...NER TRAY LDSHOWN SEE NEXT PAGE FOR DETAIL 50 51 52 53 54 66 60 59 61 62 65 UNITED STATES CANADA UNITED STATES CANADA UNITED STATES 82 82 85 85 101 102 103 104 105 106 107 108 HEAT EXCHANGER SEE NEXT P...

Страница 26: ...6 14 8 5 2 1 4 34 16 18 70 98 96 97 75 72 75 74 38 32 95 86 85 49 48 69 47 44 45 80 77 79 78 81 90 93 88 94 91 39 30 31 43 76 87 23 22 36 28 34 26 33 25 LD SHOWN 29 27 35 3 12 LG SHOWN 19 24 13 20 LG...

Страница 27: ...Model LG LD Pool and Spa Heater Page 25 NOTES...

Страница 28: ...thorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of...