Caution

Do not mount the TeleLink PCB in the

AquaLink Power Center. Keep in original

TeleLink enclosure.

!

The TeleLink enclosure will need to be installed as close as possible to a phone jack to keep the phone cord as

short as possible between the phone and the TeleLink. The TeleLink will need the phone cord to communicate with
the house phone. Run the 4-conductor wire from the TeleLink either to the AquaLink Power Center (connect to the
red 4-pin terminal bar) or the AquaLink indoor controller (connect to the red 4-pin terminal bar, the wires may be
doubled-up on the terminal bar). If running the 4-conductor wire to the AquaLink RS Power Center, use a strain
relief on one of the knockouts on the bottom of the Power Center.

NOTE: If you are installing more than one accessory board, order and use a Jandy Multiplex PCB Kit,

(p/n 6584). Never put more than two wires into each of the pins of the red terminal bar. Use the Multiplex PCB
whenever more than two of the 4-conductor wire are being connected.

AquaLink

® 

RS TeleLink 

Telephone Interface

Installation Instructions- Jandy part #6590