Jandy AquaLink RS Conversion Kit Скачать руководство пользователя страница 1

H0669200_REVF

FOR YOUR SAFETY - 

This product must be installed and serviced 

by a contractor who is licensed and qualified in pool equipment by the 

jurisdiction in which the product will be installed where such state or 

local requirements exist, the maintainer must be a professional with 

sufficient experience in pool equipment installation and maintenance 

so that all of the instructions in this manual can be followed exactly. 

Before installing this product, read and follow all warning notices and 

instructions that accompany this product. Failure to follow warning 

notices and instructions may result in property damage, personal 

injury, or death. Improper installation and/or operation may void the 

warranty. Improper installation and/or operation can create unwanted 

electrical hazard which can cause serious injury, property damage, or 

death. Turn off all circuit breakers required in order to 

prevent the possibility of electric shock

ATTENTION INSTALLER: 

This manual contains 

important information about the installation, operation 

and safe use of this product. This information should 

be given to the owner/operator of this equipment.

                 WARNING

AquaLink

®

 RS Conversion Kit  

for Pentair

®

 Enclosures 

Installation Instructions

Содержание AquaLink RS Conversion Kit

Страница 1: ...ns that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or operation may void the warranty Im...

Страница 2: ...ection 5 Install the AquaLink RS Conversion Kit 16 5 1 Apply the New Wiring Label 16 5 2 New Transformer Installation 17 5 3 Install Conversion Kit 18 5 4 Connect Sensor Wires 19 5 5 Connecting Heater...

Страница 3: ...e local installation codes and regulations must be followed ATTENTION The power center and the chlorine generator control center are not to be considered as suitable for use as service equipment There...

Страница 4: ...otected by a ground fault circuit interrupter Refer to local codes for complete details CAUTION This device is intended for use with permanent swimming pools and may also be used with hot tubs and spa...

Страница 5: ...mpending danger Failure to perceive heat Failure to recognize the need to exit spa Physical inability to exit spa Fetal damage in pregnant women Unconsciousness resulting in a danger of drowning To Re...

Страница 6: ...a chlorine generator without water flowing through the cell may cause a build up of flammable gases resulting in fire or explosion Keep equipment out of reach of children A damaged supply cord should...

Страница 7: ...at it shall not allow for separate or independent shutoff or isolation of each drain See Figure 1 More than one 1 pump can be connected to a single suction line as long as the requirements above are m...

Страница 8: ...to Main Drain Sump At Least 3 Feet Suction Outlet Main Drain Suction Outlet Main Drain Valves permitted only after tee Pump No valves between Tee and Main Drains Skimmer SAVE THESE INSTRUCTIONS Aquali...

Страница 9: ...Transformer Bracket 1 4 PIB Bracket 1 5 System Level Board Hinge 1 6 iQ20 Web Connect Device 1 7 Low Voltage Dead Front 1 8 Enclosure Conversion Wiring Diagram Label 1 9 Professional Installation Req...

Страница 10: ...ion Kit for use with the following equipment EasyTouch EasyTouch PL4 PLS4 IntelliTouch IntelliCenter All respective brands and trademarks are property of Pentair Corporation Replace with Jandy One Tou...

Страница 11: ...ctor as you remove it with the relay number name and function WARNING Risk of electric shock which can result in serious injury or death Before attempting to install or service ensure that all power t...

Страница 12: ...mark them intake and return 8 Disconnect the Ethernet cable see Figure 4 a 9 Unplug the auxiliary relays see Figure 4 b a b Figure 4 Unplug Auxiliary Relays 10 Unplug RS 232 including saltboard if on...

Страница 13: ...retaining screws on top of the High Voltage cover panel see Figure 6 a 17 Remove the High Voltage cover panel from enclosure 18 Remove 2 inner retaining screws from Pentair control panel see Figure 6...

Страница 14: ...7 a a Figure 7 Remove Dead Front Screws 3 Remove the High Voltage cover panel from enclosure 4 Locate existing transformer and unplug it 5 Remove existing transformer wires from resettable fuses see F...

Страница 15: ...l Screws 9 Disconnect power connection from the transformer 10 Unplug Valve actuator s mark them intake and return 11 Disconnect the Ethernet cable see Figure 10 a 12 Unplug the auxiliary relays see F...

Страница 16: ...ove Circuit Breaker Assembly Section 5 Install the AquaLink RS Conversion Kit 5 1 Apply the New Wiring Label 1 Place AquaLink RS Conversion wiring diagram label over existing Pentair wiring diagram on...

Страница 17: ...nsure all screw holes and openings not being used are properly closed off and sealed 2 Wire new transformer to 120 VAC If applicable use supply previously connected to the Pentair transformer 3 Connec...

Страница 18: ...gure 14 a 2 Slide 3 tabs on AquaLink RS Conversion Kit PIB into the slots in bracket see Figure 14 b 3 Secure AquaLink RS Conversion Kit PIB onto bracket with 2 top screws 4 Slide pins on AquaLink RS...

Страница 19: ...board see Figure 15 Figure 15 Connect Sensors to Green Terminal Bar NOTE If a solar system is installed the Freeze Air Sensor will become the Solar Sensor A special Freeze Sensor Kit Part 6996 is need...

Страница 20: ...switch on 5 Do not disconnect the high limit or pressure switches NOTE For Spa Heater make connection to the Spa heater Interface Board and plug it into the Spa Heater socket 5 6 Connecting Auxiliary...

Страница 21: ...check continuity to ground for all metal parts 2 Put the system into Service mode 3 While in Service mode each auxiliary can be toggled to ensure that the equipment is functioning and that it is conne...

Страница 22: ...when solar is activated to ensure air is purged from the system AquaLink RS Control Panel display reads CLEANER rather than AUX 1 S1 DIP 2 ON AUX 2 Controls Low Speed of Spa Pump Turn this switch ON...

Страница 23: ...used Set this switch to OFF if Solar Priority is to be used AquaLink RS Conversion Kit available accessories All Button Indoor Controller OneTouch Indoor Controller Wireless Remote AQWHR18 dedicated w...

Страница 24: ...r Heating system If a solar sensor is connected to the solar sensor input The AquaLink RS will be able to control a Heat Pump The AquaLink RS will not be able to control a Solar Heating system 6 3 DIP...

Страница 25: ...lementation OFF Sensor installed Not connected In this configuration there is no Solar Heating There is a mechanically connected Heat Pump There is Heat Pump Priority full implementation OFF Sensor in...

Страница 26: ...Page 26 NOTES Jandy AquaLink RS Conversion Kit...

Страница 27: ...Page 27 NOTES Installation Operation Manual...

Страница 28: ...l other trademarks are the property of their respective owners H0669200_REVF Classified to UL STD 1563 CSA C22 2 No 218 1 ETL CLASSIFIED Zodiac Pool Systems LLC 2882 Whiptail Loop 100 Carlsbad CA 9201...

Отзывы: