42
Force Control Products
Figure 2-38 Installation and Dimensions of the Sensor
2.1.6.3 Wiring of the Sensor
This sensor is connected via USB, that is, you need to connect the sensor USB to the USB port on the control
cabinet panel.
The connecting cable is provided with the product. It is a multicore cable that is directly connected to the
sensor, as shown in Figure 2-39. During installation, each cable core should be wired in strict accordance with
the specified core color definitions (the wiring diagram is shown in Figure 2-40). Leads 485-A and 485-B
should be connected to the 422/485-USB adapter; Leads power+ and power- should be connected to a 24V
DC power supply; Leads TX and RX do not need connection; and the shielding lead can be grounded if the
quality of the sensor signal is not good enough.
Figure 2-39 Cable Connection
Содержание Zu Series
Страница 1: ...JAKA ROBOTICS Force Control Products JAKA Se and JAKA Sp...
Страница 3: ......
Страница 4: ......
Страница 17: ...Version 3 1 0 13 M3 2 0 M4 4 0 M5 8 0 M6 13 0 M8 35 0...
Страница 41: ...Version 3 1 0 37 Figure 2 36 Installation and Dimensions of the Force Sensor Indicator light...
Страница 61: ...Version 3 1 0 57 Figure 3 8 Force Display Interface of the App...
Страница 75: ...Version 3 1 0 71 Figure 3 19 Force Display Interface of the App...
Страница 79: ...Version 3 1 0 75 Figure 3 21 Collision Detection Function Settings of JAKA Zu Sp...