Electronic Shutter
Related Setting Items:
How to Compensate Lateral Chromatic Aberration
When you use this function, you can set the exposure to a preconfigured accumulation time,
regardless of the line rate.
RGB
SWIR
Variable Range
3 μs ~ 15149.07 μs
20.38 μs (1L) ~ 1994.90 μs
Variable Unit
0.01μs (1clk)
0.1499 μs (1clk)
Supported Operation Mode
Trigger Mode = On / Off
Exposure Mode = Timed
Caution:
In “Trigger Mode Off, Exposure Mode Timed” mode, the line rate configured will be
the maximum value at which the shutter operates. However, in “Trigger Mode ON, Exposure
Mode Timed” mode, the input trigger period will be the maximum value.
Notes:
l
The exposure offset duration for the RGB channels is -0.85 μs. The SWIR channel does
not have exposure offset duration.
l
You can also save the setting, and have it applied whenever the power is subsequently
turned on, but this requires additional operations.
l
Switching and settings changing and storage for this function is performed via serial
communication.