SW-4010Q-MCL-M52 User Manual (Tentative)
Preparation
- 26 -
Configure Trigger, Exposure, and Line Rate Settings
This section describes how to control the exposure time with or without external triggers.
Note:
For the detailed setting information, see
Short ASCII Commands for Trigger, Exposure,
Control via External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
1. First, configure the RGB channels. Set
Exposure Mode
to
Timed
. (Timed = Default).
2. Specify the Exposure Time in
Exposure Time
. For the RGB channels, you must configure
each R, G, and B channel individually.
3. Set
Trigger Mode
to
On
.
4. Configure the
Trigger Source
and
Trigger Activation
settings if necessary.
5. Second, configure the SWIR channel. Repeat steps 1 through 4 to configure.
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
1. First, configure the RGB channels. Set
Exposure Mode
to
Timed
. (Timed = Default).
2. Set
Trigger Mode
to
Off
. (Off = Default)
3. Specify a line period slower than the exposure time in
Acquisition Line Rate
.
4. Specify the Exposure Time in
Exposure Time
. For the RGB channels, you must configure
each R, G, and B channel individually.
5. Second, configure the SWIR channel. Repeat steps 1 through 4 to configure.
When Not Controlling the Exposure Time
1. First, configure the RGB channels. Set
Exposure Mode
to
Off
. (Off =Default)
The exposure will be performed with an exposure time equal to 1 / line rate.
Note:
The exposure time specified in ExposureTime will be disabled.
2. Second, configure the SWIR channel. Repeat step 1 to configure.