SP-5000M-GE2 / SP-5000C-GE2
- 69 -
7.5.2 If the overlap setting is “Readout”
Trigger
CCD
Exposure
XEEN
FVAL
Exposure
Active
Exposure Period
t5
t1
t2
t3
t4
Fig.35 Readout
7.6. Trigger width mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer
exposure times are supported. Additional settings determine if the trigger pulse can be accepted
during the exposure period.
The frame rate of full pixels readout is 44 fps.
Primary settings to use this mode
Exposure Mode:
Trigger Width
Trigger Mode: ON
Trigger Option: OFF
7.6.1 If the overlap setting is “OFF”
Trigger
CCD
Exposure
XEEN
FVAL
Exposure
Active
Exposure Period
t6
t1
t2
t3
t4
t5
Fig.36 Overlap = OFF
t1
t2
t3
t4
t5
2L
30
µ
s
10.13
µ
s
2.51
µ
s
8L to 9L (18.142
µ
s)
t1
t2
t3
t4
t5
t6
2L (Min)
30
µ
s
10.158
µ
s
2.75
µ
s
226 ns
7L to 8L