background image

Thank you for purchasing this product.

 Be sure to read this manual before use.

This manual includes important safety precautions and instructions on 

how to operate the unit. Be sure to read this manual to ensure proper 

operation.

© 2016 JAI

User Manual

SP-12000M-CXP4

SP-12000C-CXP4

12M Digital Progressive Scan

Monochrome and Color Camera

Document Version: 1.0

SP-12000-CXP4_Ver.1.1_Sep.2016

Содержание SP-12000M-CXP4

Страница 1: ...udes important safety precautions and instructions on how to operate the unit Be sure to read this manual to ensure proper operation 2016 JAI User Manual SP 12000M CXP4 SP 12000C CXP4 12M Digital Prog...

Страница 2: ...22 Step 7 Saving the Settings 23 To save user settings 23 To load user settings 24 Basic Function Matrix 24 Main Functions 25 GPIO Digital Input Output Settings 25 Valid Input Output Combinations 25 A...

Страница 3: ...ested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...

Страница 4: ...of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period of...

Страница 5: ...of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period of...

Страница 6: ...sensors The following phenomena are known to occur on cameras equipped with CMOS image sensors These do not indicate malfunctions Aliasing When shooting straight lines stripes and similar patterns ver...

Страница 7: ...s also supported Output formats You can choose from 8 bit and 10 bit output for both monochrome and Bayer in normal mode 12 bit output is possible in Video Process Bypass mode see page 48 High frame r...

Страница 8: ...8 SP 12000M CXP4 SP 12000C CXP4 Parts Identification SP 12000 CXP4 SP 12000 CXP4 XT option...

Страница 9: ...mber rapid Detecting link when using PoCXP Blinks for 1 s even when detected immediately Alternating between green and amber slow Sending connection test packet Blinking red green amber slow Complianc...

Страница 10: ...se Electronic HR10A 10P 12S 73 Pin No Attribute Name Note 1 GND GND 2 Power IN DC 12V IN DC 12 V to 24 V 10 3 GND GND 4 NC 5 IN Opto IN Line 5 6 IN Opto IN 7 OUT Opto OUT Line 2 8 OUT Opto OUT 9 OUT T...

Страница 11: ...ristics of the recommended circuits for Opto OUT OUTPUT LINE RESPONSE TIME Output Line Voltage Camera Output Signal RT TDR TDF FT 90 10 Output LEVEL User Vcc 0 8 to 1 1 When 270 terminals are used Use...

Страница 12: ...50 10P C 50 Pin No Attribute Name Note 1 OUT TTL OUT2 Line 8 2 OUT TTL OUT3 Line 9 3 IN TTL_IN2 Line 10 4 NC 5 GND GND 6 IN LVDS_IN1 Line 11 7 IN LVDS_IN1 8 NC 9 GND GND 10 GND GND 8 Camera locking sc...

Страница 13: ...first time only When using the camera for the first time install the software for configuring and controlling the camera JAI SDK on the computer When you install JAI SDK JAI Camera Control Tool will a...

Страница 14: ...rd under 64 bit Factory Transport Layers Available 64 bit Transport Layers to display its settings 4 Set Enabled to True Step 2 Connecting Devices Connect the lens CXP cable AC adapter and other devic...

Страница 15: ...les to the CXP connectors on the camera and the frame grabber board The number of cables you can connect varies depending on the number of connectors on your frame grabber board 1 2 or 4 Be sure to co...

Страница 16: ...ions After initialization is completed once the power trigger LED will remain green even if the host is disconnected Step 4 Configuring Initial Settings for the Camera Start Control Tool connect the c...

Страница 17: ...xels Pixel Format SP 12000M CXP4 8 Bit Monochrome SP 12000C CXP4 8 Bit Bayer GB You can specify the image acquisition area For details see ROI Regional Scanning Function page 39 1 Select the Feature P...

Страница 18: ...Trigger Activation trigger polarity Rising Edge rising edge of input signal Trigger Overlap Read Out Trigger Option Off Exposure Mode Timed control via exposure time Exposure Time 10486 s Exposure Aut...

Страница 19: ...isition Frame Rate Raw value 1 Set Exposure Mode to Timed Timed is the default setting 2 Specify the exposure time in Exposure Time The setting value for the exposure time can only be changed when Exp...

Страница 20: ...cified Exposure Times Configure the settings as follows Item Setting value selectable range Trigger Selector trigger operation Frame Start Trigger Mode Off Exposure Mode Timed control via exposure tim...

Страница 21: ...Auto to Off Off is the default setting 2 Configure the digital gain u Expand Analog Control and select the gain you want to configure in Gain Selector For the SP 12000M CXP4 only Digital All master g...

Страница 22: ...ts near the subject such as a white cloth or wall can also be used Be sure to prevent the high intensity spot lights from entering the screen 2 Select the Balance White Auto tab and click Continuous o...

Страница 23: ...ory Current setting values Control Tool Save User Set1 User Set2 User Set3 Note The setting values are not saved to the computer Control Tool The setting values will be stored in the camera s temporar...

Страница 24: ...User Set Load Command The selected user settings are loaded Basic Function Matrix The combinations of settings for the basic functions that can be used together are as follows Exposure Mode Trigger M...

Страница 25: ...ollowing Selector Cross point switch output Source signal Cross point switch input Output destination Trigger Selector Line Selector Pulse Generator Selector Acquisition Start Acquisition End Frame St...

Страница 26: ...the ROI pixel format and binning mode selected The longest frame period is 0 125 Hz 8 sec When Trigger Mode is enabled the Acquisition Frame Rate setting is disabled Maximum Frame Rate The maximum fra...

Страница 27: ...e during Binning Vertical Only Monochrome is available during Binning On Caution Although the maximum frame rate value is determined by the CXP bandwidth range when ROI is configured the frame rate ca...

Страница 28: ...sure in response to the external trigger signal input Select this to perform exposure control using external triggers Acquisition Start Start image acquisition in response to the external trigger sign...

Страница 29: ...xposure Trigger Valid data Period Height x Line Period Next trigger start prohibited period Next trigger input allowed period Trigger overlap Readout EEN FVAL A2 Sensor Exposure Trigger Exposure Time...

Страница 30: ...2 4 to 29 4 385 9 18 7 3G 1 10 12 19 2 4 2 4 to 15 8 306 4 24 1 Formulas for each Link Config Link Config Dig Bit Sensor Dig Bit Frame Rate Hz Period from trigger start to exposure start A1 Period fr...

Страница 31: ...10 bit minimum 4 0 to 4 0 1L 0 6 to 0 6 1L 14L to 15L Trigger overlap Off Sensor Exposure EEN FVAL A1 B C D1 Trigger Valid data Period Height x Line Period Next trigger start prohibited period Next t...

Страница 32: ...40 2 4 to 29 8 385 9 1 6 3G 1 10 12 19 2 40 2 4 to 15 8 306 8 1 9 Formulas for each Link Config Link Config Dig Bit Sensor Dig Bit Frame Rate frequency fps Period from trigger start to exposure start...

Страница 33: ...ange Shortest period trigger Full 10 555 ms ROI 2 3 Height 2048 Width 2720 4 964 ms ROI 1 2 Height 1536 Width 2048 3 380 ms ROI 1 4 Height 768 Width 1024 1 728 ms ROI 1 8 Height 384 Width 512 0 903 ms...

Страница 34: ...culate Line Time Example When the max frame rate is used Link Config Dig Bit Sensor Dig Bit Frame Rate Hz Period from trigger start to exposure start A usec Period from 1st exposure end to 1st FVAL st...

Страница 35: ...chart Trigger Off Exposure Mode Off Timed Continuous Shutter Off Shutter Mode Example When the max frame rate is used Link Config Dig Bit Sensor Dig Bit Frame Rate frequency fps FVAL Blanking FVAL EE...

Страница 36: ...pending on the camera s settings Refer to the maximum frame rate formula on page 27 for the formula used to calculate Line Time Gain Control Digital gain is used for gain control on the camera R and B...

Страница 37: ...Configure the settings as follows Item Setting value selectable range Description JAI LUT Mode LUT Use LUT LUT Selector R G B Select the LUT channel to control LUT Index SP 12000M CXP4 0 to 255 SP 120...

Страница 38: ...ker or the gradation in the dark areas may be less noticeable when camera outputs are displayed without processing The gamma function can be used to correct the camera signals with an opposite directi...

Страница 39: ...ight as the number of lines scanned decreases The minimum area is as follows Width pixels Height pixels SP 12000M CXP4 Binning Off 128 Binning 2 On 256 The minimum value for Monochrome varies dependin...

Страница 40: ...at Index 1 Command Sequence Mode Sequence Trigger mode that executes the preset listed in Command Sequence Index each time a trigger is received Can jump to new preset by sending a new index value to...

Страница 41: ...is index before moving to the next Next Index to execute in the predetermined pattern In addition to these individual index parameters two other parameters are applied to the entire sequence Sequence...

Страница 42: ...is index The user must also enter a value from 1 to 128 in Command Sequence Index This indicates which index to execute each time a trigger is received The same index will continue to be executed for...

Страница 43: ...Set to Index2 Index1 Settings Index3 Settings Index1 Settings Index2 Settings Index1 Settings Index2 Settings Settings Used Index structure for Command Sequence Index1 ROI1 Exposure1 Gain1 Black Leve...

Страница 44: ...100 video levels will be maintained at 100 for AGC and ASC Automatic gain level control Set Gain to Continuous Detailed Settings for Gain Auto Automatic Gain Level Control When Gain Auto is set to Co...

Страница 45: ...osure and scanning twice in succession in response to a single trigger This is useful in situations that require quick successive image scans The durations for the first and second exposures are diffe...

Страница 46: ...ns during HDR mode Exposure duration Scan duration Knee Point 2 setting range Knee Point 1 setting range Exposure Time Knee Slope 2 or lower Item Setting value selectable range Description HDR Mode On...

Страница 47: ...Exposure Time Knee Slope 2 Knee Point 2 10 to 120 step 1 Unit Adjust the output level for knee point 2 You can determine the knee point 2 value using the following formula Exposure Time Exposure Time...

Страница 48: ...8 bit 10 bit 12 bit 10 bit 12 bit When bypass is enabled the sensor output and camera output data can be set to the same bit width Operating using 12 bit outputs must be performed in bypass mode CXP o...

Страница 49: ...ceFirmwareVersion Displays the firmware version DeviceFpgaVersion Displays the FPGA version DeviceFirmware2Version Displays the CPU2 firmware version not used DeviceFpga2Version Displays the FPGA2 fir...

Страница 50: ...rtical Ramp Grey Horizontal RampMoving HorizontalColorBar color only VerticalColorBar color only MovingColorBar color only Off Select the test image TapGeometry 0 Tap_1X_1Y 0 Tap_1X_1Y Displays the Ta...

Страница 51: ...alanceWhiteAuto Off On Off Enable disable auto white balance LutMode Off Gamma LUT Off Select the JAI LUT mode Gamma 1 0 to 0 45 0 45 Set the gamma value e Digital IO Control Configure settings for di...

Страница 52: ...t clear input signal g LUTControl Configure LUT settings LutSelector R G B R Select the LUT channel to control LutIndex 0 to 255 0 Set the LUT index table number LutValue 0 to 4095 0 Set the LUT value...

Страница 53: ...n will stop with this index SequenceRoiWidth 128 to 4096 16 steps 4096 Set the width SequenceRoiHeight 16 to 3072 2 steps 3072 Set the heigh SequenceRoiOffsetX 0 to 3968 16 steps 0 Set the horizontal...

Страница 54: ...t value Counter0 to 3 Status Counter Active Displays the counter status Settings For details on the setting items refer to the JAI Control Tool User s Guide Item Setting range Default value 32 bit Fac...

Страница 55: ...lugins Enable the plug in button on the menu tab True False False Support Open settings file after save True False True Support EMail Address camerasupport jai com Logging Properties Enable logging Tr...

Страница 56: ...o correct the display As the light emitting properties of the monitor are not linear the entire image may be darker or the gradation in the dark areas may be less noticeable when camera outputs are di...

Страница 57: ...ines step Offset Y 0 to 3056 2 lines step 0 to 3056 2 lines step Binning H 1 4096 H 4096 H 2 2048 H V 1 3072 V 3072 V 2 1536 V Pixel Format Mono8 Mono10 BayerGB8 BayerGB10 Acquisition modes Continuous...

Страница 58: ...input full pixel Typical Option XT model with fan 1040 mA Power consumption 12 0 W at 12 V input full pixel Typical Option XT model with fan 12 48 W PoCXP Input range DC 24 V 2 V Current 500 mA at 24...

Страница 59: ...mm diagonal 574 fps 8 bit 381 fps 10 bit 1 3 MP 1280 1024 1280 1024 ROI 5 5 5 5 1 1 8 9 02 mm diagonal 589 fps 8 bit 391 fps 10 bit 0 5 MP 800 600 800 600 ROI 5 5 5 5 1 2 9 5 50 mm diagonal 987 fps 8...

Страница 60: ...P 12000M CXP4 SP 12000C CXP4 SP 12000C CXP4 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 400 500 600 700 800 900 1000 1100 Relative Response wave length nm SP 12000C Spectral Sensitivity Rch Gch Bch Dimens...

Страница 61: ...arks Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries Intel and Intel Core are trademarks of Intel Corporation in the Uni...

Страница 62: ...o 44 Gain Control 36 Gain Level 44 Gamma Function 38 GPIO 25 H HDR Mode 46 High Dynamic Range 46 I Initial Settings for the Camera 16 Installing the Software 13 J JAI Camera Control Tool 13 JAI SDK 13...

Страница 63: ...Revision History Revision Date Changes 1 0 May 2016 First edition 1 1 Sept 2016 Revised frame rate frequency calculation formulas and frame rate values p 28 32 to 34 38 66...

Отзывы: