— 20 —
SP-12000M-CXP4 / SP-12000C-CXP4
1
Set [Exposure Mode] to [Trigger Width] .
When you select [Trigger Width], [Trigger Mode] will automatically be set to [On].
2
Set [Trigger Selector] to [Frame Start].
([Frame Start] is the default setting.)
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.
Other controls
In addition to exposure time, the following can also be controlled by external triggers. Select these
control operations in [Trigger Selector].
[Trigger Selector] setting
Description
Acquisition Start
Start image acquisition.
Acquisition End
Stop image acquisition.
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
Off
Exposure Mode
Timed (control via exposure time)
Exposure Time
15 (8-bit) or 20 (10-bit) to 7999892 (μs) (1 μs/step)*
1
Exposure Auto
Off, Continuous
*1 The maximum value for [Exposure Time] varies depending on the value configured for the [Acquisition Frame
Rate Raw] setting.
Max. value for [Exposure Time] = [Acquisition Frame Rate Raw] value
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the exposure
time.
3
Set [Trigger Mode] to [Off].
4
If necessary, change the [Exposure Auto] setting.