— 52 —
SP-12000M-CXP4 / SP-12000C-CXP4
Item
Setting range
Default value
Description
PreScaler
1 to 4096
1
Set the division value for the prescaler
(12-bit) using the pixel clock as the base
clock.
PulseGeneratorSelector
Pulse Generator 0,
Pulse Generator 1,
Pulse Generator 2,
Pulse Generator 3
Pulse Generator 0
Select the pulse generator.
PulseGeneratorLength
1 to 1048575
1
Set the count-up value (clock value) for
the pulse generator.
PulseGeneratorStartPoint
0 to 1048574
0
Set the active output start count value for
the pulse generator.
PulseGeneratorEndPoint
1 to 1048574
1
Set the active output stop count value for
the pulse generator.
PulseGeneratorRepeatCount
0 to 255
0
Set the repeat count for the pulse
generator.
PulseGeneratorClearActivation Off,
High Level,
Low Level,
Rising Edge,
Falling Edge
Off
Set the clear signal condition for the
count clear input of the pulse generator.
PulseGeneratorClearSource
Low, High,
Acquisition Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
User Output 0,
User Output 1,
Line4 - TTL In 1,
Line5 - Opt In 1,
Line7 - CXP In,
Line10 - TTL In 2,
Line11 - LVDS In,
Nand 0 Out, Nand 1
Out
Low
Select the count clear input signal
source.
PulseGeneratorInverter
True, False
False
Select whether to invert the polarity of the
count clear input signal.
PulseGeneratorClearSyncMode
Async Mode,
Sync Mode
Async Mode
Select the sync mode for the count clear
input signal.
g) LUTControl
Configure LUT settings.
LutSelector
R, G, B
R
Select the LUT channel to control.
LutIndex
0 to 255
0
Set the LUT index table number.
LutValue
0 to 4095
0
Set the LUT value.
h) UserSetControl
UserSetSelector
Default, User Set1 to 3
Default (factory default
values)
Select the user settings.
UserSetLoad
—
—
Load user settings.
UserSetSave
—
—
Save the current setting values as user
settings.
i) JAICustomControl
Configure JAI ALC settings. These
settings are also used for AGC (auto gain
control).
TriggerOption
Off,PIV
Off
When [ExposureMode] is set to [Timed],
select from normal trigger operation or
PIV operation.
ALCReference
10 to 100
50
Set the target level for ALC. (unit: %)
ALCAreaSelector
Low Right to High Left
Low Right
Select an ALC metering area.
ALCAreaEnable
True, False
False
"Enable/disable the metering area where
selected metering area."
ALCAreaEnableAll
0 to 1
1
Set whether to enable ALC for all areas.
AutoShutterControlExposureMin
100 to 7999998
100
Set the minimum value for the ASC
range.
AutoShutterControlExposureMax 101 to 7999999
7999999
Set the maximum value for the ASC
range.
AutoGainControlGainRawMin 100 to 1599
100
Set the minimum value for the AGC
range.
AutoGainControlGainRawMax
101 to 1600
1600
Set the maximum value for the AGC
range.
ALCControlSpeed
Min(1) to Max(8)
4
"Set the reaction speed for AGC/ASC.
These settings are also used for auto
exposure control."
AWBAreaSelector
Low Right to High Left
Low Right
Select the AWB (auto white balance)
measurement area.
AWBAreaEnable
True, False
False
Enable/disable the selected
measurement area.