User Manual (Ver.1.4) - Setting List
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 132 -
PulseGenerator
Configure pulse generator settings.
Related Topic:
Pulse Generator Item
Setting Range
Default Value
Description
ClockPreScaler
1
~
4096
297
Set the division value for the prescaler (12 bit) using
PixelClock as the base clock.
PulseGeneratorClock (MHz)
-
0.25
Set the clock used for the pulse generator. This value is
calculated using the [ClockPreScaler] value as a base.
PulseGeneratorClock = SrcFreq / ClockPreScaler
SrcFreq:74.25
PulseGeneratorSelector
0:PulseGenerator0
1:PulseGenerator1
2:PulseGenerator2
3:PulseGenerator3
0:PulseGenerator0 Select the pulse generator.
PulseGeneratorLength
1
~
1048575
25000
Set the maximum count-up value as a clock count.
PulseGeneratorLengthMs
(ms)
-
50
Set the maximum count-up value in milliseconds.
This value is calculated using the PulseGeneratorLength
value as a base. The setting range varies depending on the
ClockPreScaler value.
PulseGeneratorLengthMs = 1/PulseGeneratorClock *
PulseGeneratorLength
PulseGeneratorFrequency
(Hz)
-
20
Set the maximum count-up value as a frequency.
This value is calculated using the PulseGeneratorLength
value as a base.
PulseGeneratorFrequency = 1sec /
PulseGeneratorLengthMs
PulseGeneratorStartPoint
0
~
1048575
0
Set the start point of the High interval as a clock count.
When the counter reaches this value, the output will be 1.
PulseGeneratorStartPointMs
(ms)
-
0
Set the start point of the High interval in milliseconds. When
the counter reaches this value, the output will be 1. The
setting range varies depending on the ClockPreScaler
value.
PulseGeneratorStartPointMs = 1/PulseGeneratorClock *
PulseGeneratorStartPoint
PulseGeneratorEndPoint
1
~
1048575
12500
Set the start point of the Low interval as a clock count. When
the counter reaches this value, the output will be 0.