GO-5101M-PMCL-1 | GO-5101C-PMCL-1 | User Manual (Ver. 1.0)
Setting List
- 75 -
Pulse Generators
Related Topic:
GPIO (Digital Input/Output Settings)
Configure pulse generator settings.
Pulse Generators
Item
Setting Range
Default
Description
Clock Pre-scaler
1 ~ 4096
165
Set the division value for the pre-scaler (128-bit length)
using the pixel clock as the base clock.
Pulse Generator Clock
(MHz)
0.018127 ~ 74.25
0.45
Set the clock used for the pulse generator. This value is
calculated using the Clock Pre-scaler value as a base.
Pulse Generator Selector Pulse Generator 0
Pulse
Generator 0
Select the pulse generator.
Pulse
GeneratorLength
1 ~ 1048575
30000
Set the maximum count-up value as a clock count.
Pulse Generator
Length (ms)
0.002222 ~ 2330.166666
66.6667
Set the maximum count-up value in milliseconds. This value
is calculated using the Pulse Generator Length value as a
base.
The setting range varies depending on the Clock Pre-scaler
value.
Pulse Generator
Frequency (Hz)
0.429154 ~ 450000
15
Set the maximum count-up value as a frequency.
This value is calculated using the Pulse Generator Length
value as a base.
Pulse Generator Start
Point
0 ~ 1048574
0
Set the start point of the High interval as a clock count.
When the counter reaches this value, the output will be 1.
Pulse Generator Start
Point (ms)
0 ~ 2330.164444
0
Set the start point of the High interval in milliseconds. When
the counter reaches this value, the output will be 1.
The setting range varies depending on the Clock Pre-scaler
value.
Pulse Generator End
Point
1 ~ 1048575
15000
Set the end point of the High interval as a clock count.
Pulse Generator End
Point (ms)
0.002222 ~ 2330.166666
33.3333
Set the end point of the High interval in milliseconds.
Pulse Generator
pulse- width (ms)
0 ~ 14.1222
33.3333
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is
calculated.
The setting range varies depending on the Clock Pre-scaler
value.
Pulse Generator
Repeat Count
0 ~ 255
0
Set the repeat count for the counter. When this is set to 0, a
free counter is enabled with no repeat limit.