GO-5100MC-PGE | GO-5101MC-PGE | User Manual (Ver. 2.0)
Main Functions
- 59 -
Manual configuration
1. Select the index in
Blemish Detect Position Index
.
You can select from 0 to 255. However, configure the indexes in order starting with the smallest
index. If you skip indexes while configuring settings, interpolation may not be performed.
2. Specify the pixel points for interpolation using the
Blemish Detect Position X
and
Blemish
Detect Position Y
settings. Each point is saved to the camera's internal memory as you
configure them.
Note:
You can configure values that are within the total effective pixel area. Specify pixels
for which interpolation is not necessary as -1. If 0 is specified, the first line or first pixel will be
interpolated.
3. Set
Blemish Enable
to
True
, and execute interpolation. If False is specified, defective pixel
interpolation is disabled.