User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 53 -
1x4-1Y (1 Line Clock, Horizontal Frequency/Period)
Horizontal Timing (Continuous Trigger Mode) (2/2)
Note:
A: Operation Value; B = Calculation Value
Camera Settings
A: Operation value B: Calculation value
Tap
Geometry
Camera Link
Pixel Clock
ROI
Binning
1 line Total
clock (Unit:
clock)
Horizontal
Frequency (Unit:
kHz)
Horizontal
Period (Unit:
us)
Width
Offset
X
Height
Offset
Y
Horizontal Vertical
1X4 - 1Y
84.99 MHz
2560
0
2048
0
Off
Off
A
653.6
130.039
7.69
B
654
129.969
7.694
1280
0
2048
0
x2
Off
A
572.9
148.368
6.74
B
573
148.342
6.741
640
0
2048
0
x4
Off
A
572.9
148.368
6.74
B
573
148.342
6.741
2560
0
1024
0
Off
x2
A
653.6
130.039
7.69
B
654
129.969
7.694
1280
0
1024
0
x2
x2
A
572.9
148.368
6.74
B
573
148.342
6.741
640
0
1024
0
x4
x2
A
572.9
148.368
6.74
B
573
148.342
6.741
2560
0
512
0
Off
x4
A
653.6
130.039
7.69
B
654
129.969
7.694
1280
0
512
0
x2
x4
A
572.9
148.368
6.74
B
573
148.342
6.741
640
0
512
0
x4
x4
A
572.9
148.368
6.74
B
573
148.342
6.741