User Manual (Ver. 2.0) - Short ASCII Command List
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 110 -
User Set Control
Related Topic:
Name
Access
Short
ASCII
Values
MIN
MAX
Default
Description
UserSetLoad
(R)/W
LD
0: Default
1: UserSet1
2: UserSet2
3: UserSet3
0
3
0
LD=[Param.]<CR><LF>
LD?<CR><LF>
UserSetSave
(R)/W
SA
1: UserSet1
2: UserSet2
3: UserSet3
1
3
1
SA=[Param.]<CR><LF>
SA?<CR><LF>
JAI Custom
Name
Access
Short
ASCII
Values
MIN MAX Default
Description
AcquisitionFrame Period R/W
AR
Min ~ Max[us]
1
325786
11961
AR=[Param.]<CR><LF>
AR?<CR><LF>
Maximum value is calcurated
depending on Height and Offset
Y settings
BlemishWhite Enable
Related Topic:
R/W
BMW
0: False
1: True
0
1
0
BMW=[Param.]<CR><LF>
BMW?<CR><LF>
BlemishWhite Detect
W/O
BMRCW
1
1
1
-
BMRCW=1<CR><LF>
BlemishWhite Detect
Threshold
R/W
BMTHW
Min ~ Max [%]
0
100
10
BMTHW=[Param.]<CR><LF>
BMTHW?<CR><LF>
BlemishWhite
DetectPositionX
R/W
BMPXW
Param 1: Blemish index
Param 2: Y position
(Min ~ Max)
0
2559
0
BMPXW=[Param1], [Param2]
<CR><LF>
BMPXW? [Param1]<CR><LF>
BlemishWhite
DetectPositionY
R/W
BMPYW
Param 1: Blemish index
Param 2: Y position
(Min ~ Max)
0
2047
0
BMPYW=[Param1], [Param2]
<CR><LF>
BMPYW? [Param1]<CR><LF>