Tool change
Item no. 10404241, Revision 03
30 ( 40 )
10.2.2
Maximum tightening torques
Short clamping bore
Continuous clamping bore
Excessive tightening torques (M
A
) can damage or destroy the collet, clamping
nut, and collet mount of the shaft.
Keep to the following values.
Ü
Short clamping bore
Ä
Clamping diameter: 1,0 - 2,5 mm
Ä
Ma max.: 11 Nm
Ü
Continuous clamping bore
Ä
Clamping diameter: 3,0 - 7,0 mm
Ä
Ma max.: 18 Nm