Installation
Item no. 10408114, Revision 02
34 ( 52 )
8.4.3
Setting values
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
Ü
Keep to the following values:
Taper cleaning
4,5 - 6 bar
Pneumatic system for tool change
≥ 6,0 bar
8.5
Setting the internal coolant supply
1
Compressed air
10 bar
n = 0 rpm
5 bar
n < 1000 rpm
2
Minimum quantity cooling lubrication
max. 80 bar
3
Cooling lubricant
max. 80 bar
4
Vent
G 1/4“
5
Leakage
G 1/8“
Ü
Keep lines short.
Ü
Do not exceed the upper pressures specified.
Ü
Avoid pressure pulsation.
Ä
Max. ±5 bar.
Ü
Avoid pressure peaks.
Low-pulsation delivery(±2 bar) of media by the pump increases the service life
of the cooling lubricant system components and reduces the noise level.