ADwin
Installation, manual version 2.1, December 2005
57
ADwin System with Ethernet Interface
ADwin
ENET-2
Place the module with the front plate to the left side, so that the handle is closer
to you.
This description refers to the DIL switch block at the top of the
ADwin
Ethernet
interface printed circuit board. The DIL switch number 1 is at right, the position
OFF is upwards.
Abb. 2 – DIP switch numbers ENET-2
Description of
DIL switches
Switch "Reprogramming the firm ware"
With an
ADwin
Ethernet interface the firm ware can be reprogrammed with the
program
ADethflash
(under Windows start menu
Programs\ADwin
). In order
to reprogram, this DIL switch has to be set to "ON". At the next power-up the
ADwin
Ethernet interface is operating in a special mode, so that you can pro-
gram the firm ware with
ADethflash
.
Switch "Bootloader is write-protected"
If your
ADwin
Ethernet interface has the bootloader option (see the following
chapter 9.6), you may prevent the reprogramming of the bootloader with this
DIL switch. In the position "ON", reprogramming the bootloader is not possible.
When working with an
ADwin
Ethernet interface without bootloader option the
DIL switch is ignored.
Switch "Bootloader is not active" (ENET-1 only)
If your
ADwin
Ethernet interface has the bootloader option, you can deactivate
the bootloader with this DIL switch. In the position "ON" the bootloader is not
executed.
When working with an
ADwin
Ethernet interface without bootloader option the
DIL switch is ignored.
Switch "Configuration blocked"
With the program
ADconfig
you configure the
ADwin
Ethernet interface (see
chapter 9.3). In order to avoid an unintentional configuration, you can block the
configuration with this DIL switch. In the position "ON" the configuration of the
ADwin
Ethernet interface cannot be changed.
9.2.3 Initializing the hardware
Initializing the hardware
Before you can configure your
ADwin
Ethernet you have to connect it with the
PC. Connect the power supply cables and the network card, too (see also the
previous examples in this chapter).
DIL no.
Description
Meaning
Default setting
1
Reprogramming the firm ware
ON = active
OFF
2
Bootloader write-pro
configuration blocked
ON = yes
OFF