111
Counters
Cnt_Clear
ADwin
Cnt_Clear
Cnt_Clear
sets one or more counters to zero, according to the bit
pattern
.
Syntax
#Include
ADwinGoldII.inc / GoldIITiCo.inc
Cnt_Clear
(
pattern
)
Parameters
Notes
After
Cnt_Clear
has been executed the bit pattern is automatically re-
set to 0 (zero), so the counters start counting from 0.
Please pay attention to set
Cnt_Mode
parameter
pattern
to bit 1=0 for
the appropriate counters. Else, with bit 1=1, the counter inputs
A
,
B
have
also to be set to TTL level high, in order to clear the counter.
See also
,
,
,
,
,
Valid for
Gold II-CNT
T11 TiCo
pattern
Bit pattern.
Bit = 0: no influence.
Bit = 1: set counter to zero.
LONG
Bit no.
31…4
3
2
1
0
C o u n t e r
no.
–
4
3
2
1