JAGAUK cocoon 03.03
INSTALLATION INSTRUCTIONS
COCOON
Contents:-
Chrome
blank plug
Air Vent
Screws
Washers
Rawl Plugs
Always retain label
with element until installation
is complete. This will assist in
casing pack selection (see fig. 6)
Number of brackets
required for casing
lengths:-
40cm to 120cm = 2
140cm to 220cm = 3
240cm to 300cm = 4
Cut away ends of shrink wrap, remove fitting
kit and push fit brackets onto end element plate.
Illustration shows brackets fitted for right hand
connections.
Fit central
support feet
if unit is
140cm long
or above, see
instructions
packed with
feet.
H = 20.5cm (205mm)
from finished floor
H = 20.5cm (205mm)
from finished floor
Offer up unit and mark wall fixings,
positioning underside of heat exchanger
205mm above finished floor level
Number required for
casing lengths:-
40cm to 120cm = 0
140cm to 220cm = 1
240cm to 300cm = 2
FITTING PACK
POSITIONING DETAILS
RIGHT HAND CONNECTIONS
LEFT HAND CONNECTIONS
HEATING ELEMENT
FIXING BRACKETS
CENTRAL SUPPORT
FEET
(Kit is located within shrink
wrap of element)
Fig. 1
Drill 8mm holes, fit Rawl plugs
and screw unit to wall.
Fig. 4
Fit valves and connect pipe
work. Units can now be filled
and tested,
but do not fit TRV
head at this point.
If top valves are being used
refer to instructions packed
with valve kits.
Fig. 5
Each front panel is 10cm high.
4 bracket nibs = 40cm plus
20cm to floor = casing height
required
60cm (600mm)
Element Label
L50, Type 10
Casing pack
required
60. 50. 10.
H L
D
When fixing and pipe work complete. Assemble casings as overleaf
Fig. 6
Fig. 2
Fig. 3
Alternatively,
if you need
left hand
connections –
turn bracket
through 180°
before clicking
onto heat
exchanger
205mm
Example. Casing pack selection.