16 Appendix A: Sargas Antenna and Cable Information
16.1 Authorized Antennas
To comply with FCC requirements for RF exposure safety, a separation distance of at least 25 cm (8.7
inches) must be maintained between the radiating elements of the antenna and nearby people. You must
also provide strain relief for all Reader connections.
The only antennas authorized by the FCC for use with the Sargas Reader are listed in the table
below. Detailed information on each antenna is available from their respective manufacturers.
Antennas not included in this list or having a gain greater than 6 dBiL are strictly prohibited for use
with this device. The required antenna impedance is 50 ohms
16.1.1
Table 6: Authorized Antennas
Manufacturer
Type
Manufacturer Part
Number
Max. Linear Gain
(dBiL)
Laird
Patch
S9025P
4.3
Laird
Patch
S8658WPL
6.0
MTI
Patch
MT-262013
6.0
MTI
Patch
MT-242043
6.0
MTI
Patch
MT-242025
5.1
Axiom Wireless Tech
Ceramic Patch
MPAC29SE921P-TA
-3.0
Laird
Dipole
FG9026
6.0
NOTE:
IMPORTANT:
Only similar antennas with the same or lower gain may be used with the Sargas Reader
without violating FCC regulations. It is the responsibility of the user to comply with this requirement.
16.2 Authorized Cables
The following table contains the cable loss values for authorized shielded coaxial cables provided by
ThingMagic Use of these cables requires an RP-SMA to RP-TNC adapter.
Cable Description
ThingMagic Part Number
Insertion Loss
6' RTNC to RTNC Cable
CBL-P6
0.8 dB
12' RTNC to RTNC Cable
CBL-P12
1.5 dB
20' RTNC to RTNC Cable
CBL-P20
2.4 dB
20' RTNC to RTNC Plenum Cable CBL-P20-PL
2.4 dB
25' RTNC to RTNC Cable
CBL-P25
3.0 dB