background image

and the HEATER knob set to the desired tempera-
ture, the timer will activate the heater and filter pump
to operate during the time period set on the timer.
With the SYSTEM switch turned OFF and the
HEATER CONTROL knob turned to its lowest set-
ting, the water will be filtered without heat during the
time period set on the timer.

• Close the redwood skirt door.

8

PUSH IN ONE TAB
FOR EACH TWO
HOUR PERIOD OF
OPERATION

TIMER

CIRCUIT
BREAKER
BUTTONS

HIGH TEMPERATURE
SAFETY RESET BUTTON

OPERATION

Basic Control Set-Up 

(continued)

• Make sure the circuit breakers are in the ON (1) position.

• Locate the HIGH TEMPERATURE SAFETY

SWITCHES which are raised buttons on the end of the
heater.  Push both buttons to be sure it is in the reset
mode.  The purpose of both switches is to shut down the
spa if the water becomes excessively hot.  If, for some
reason, the switches are tripped, the reset button must
be pushed in for the heater to operate again after the
water has cooled to about 38

°

C (100

°

F).

• Set the built-in timer (see below).  Use of the timer allows

two modes of operation: timed HEATER/FILTER and
FILTER ONLY.  With the SYSTEM switch turned OFF

Setting the Timer

The built-in 7-day timer is located in the System Control

Module. The tooth-like tabs that are located on the dial can
be set to activate the filter system for two-hour period on
any day(s) of the week.  First turn the program dial gradually
clockwise until the day of the week (7-day timer) and time
of day on the outer dial is aligned with the triangle marker
on the inner dial (two o’clock position).  For to-the-minute
setting turn the minute hand clockwise to the exact time of
day. NOTE:  Both the correct time and day must be set.
Next slide one of the tabs outward to the time at which you
wish the filter system to operate.  Note that the timed mode
can begin at any time of day or night at any specified day
of the week.

Содержание The Quantum Plus

Страница 1: ...TM Portable Whirlpool Spa Owner s Manual The Quantum Plus...

Страница 2: ...tion pump and may cause a fire Read manufacturer s safety information provided with all optional equipment Jacuzzi Whirlpool Bath does not recommend spa water temperatures in excess of 40 C 104 F High...

Страница 3: ..._______________________ 11 Silent Air Induction _______________________________________ 11 Filtration _______________________________________________ 11 Maintenance ___________________________________...

Страница 4: ...ftwopatented front loadskimmer filtersformaximumefficiency Theunique 4 65m2 50 sq feet filtration system designed by Jacuzzi Whirlpool Bath allows easy access from inside the spa to both filter cartri...

Страница 5: ...kirt panels and the acces sory package which contains the Owner s Manual filter cartridges and extra lenses and bulbs Set aside skirt panels until equipment set up Set aside the filter cartridges in a...

Страница 6: ...mes from the factory requires a 230 VAC 50 AMP 4 wire grounded type electri cal service and must be in a separate circuit having no otherapplianceconnectedinthatcircuit Ifyoudonothave this kind of cir...

Страница 7: ...nstallation If you install the spa outdoors we recommend that you provide a concrete pad for it to rest on To do this construct forms for a 8 x 8 x 4 thick level pad Install a 10 gauge wire mesh appro...

Страница 8: ...plastic sheet covering the spa Use care stepping into the spa with shoes will scratch the acrylic surface 2 Remove any packing materials from the spa 3 Remove each filter cartridge from its plastic ba...

Страница 9: ...position Move the switch to the ON 1 position to reset If the interrupter fails to operate in this manner there is a ground current flowing or a device malfunctioning indicating the possibility of ele...

Страница 10: ...e reason the switches are tripped the reset button must be pushed in for the heater to operate again after the water has cooled to about 38 C 100 F Set the built in timer see below Use of the timer al...

Страница 11: ...FILTER The next selection is OFF again Use the JETS function as a reference to indicate your location in the function sequence since that function is the most obvious when operating For best performan...

Страница 12: ...as just turned off the indicator lamp on the control panel will turn off at this time 10 OPERATION Temperature Control Turn on the heater by selecting the HTR FILTER mode on the SYSTEM selector switch...

Страница 13: ...fully adjustable jets will dramatically increase the Water Rain bow flow CAUTION The water circulating through the Water Rainbow spouts is not fresh water and therefore is not suitable for drinking A...

Страница 14: ...its pores The addition of clarifier will make the water clearer but clogged filters must be cleaned as prescribed under the section entitled Filter Maintenance in this manual Hard Water Add a de miner...

Страница 15: ...used heavily change the water at least every month pH A chemical term used in expressing relative acid ity or alkalinity in numeric values with 7 0 usually regarded as neutral and for purposes of this...

Страница 16: ...nd winds etc accumulate in the spa and cannot be filtered out it is necessary to drain your spa and refill it with fresh water This should be done every 2 months or more often depending on the amount...

Страница 17: ...idges clean them and store them dry 5 Keep water and debris out by covering with a rigid spa cover 6 Before using the spa again review the Operating In structions CAUTION Not winterizing will cause ir...

Страница 18: ...n forced polyester resin A catalyst causes a chemical reac tion during manufacture that bonds these layers perma nently into a hard strong material With a minimum amount of care and cleaning your whir...

Страница 19: ...Heater not functioning but heater light on A B C A Clogged or blocked suction strainer or skimmer basket B Filter clogged dirty C Poor water chemistry D Insufficient filtering time E Improper mainten...

Страница 20: ...our power company A Turn on power at service panel B Select other function C Reset circuit breaker D Reset circuit protector E Reset button s on heater after water has cooled see Note if switch contin...

Страница 21: ...D Inadequate supply wiring E High temperature safety switches tripped A Let cool for one hour Motor overload protector will reset if problem persists see Note B C D Consult electrician to cor rect wir...

Страница 22: ...Do not interconnect water supply with recirculating system of the spa To make the connections necessary to use the Water Rainbow as a fill spout follow this procedure Make sure spa is unplugged and c...

Страница 23: ......

Страница 24: ...vailable on a national basis for products of this type It is the responsibility of the installer owner to determine specific local code compliance prior to installation of the product Jacuzzi Whirlpoo...

Отзывы: