background image

SUMMER RAIN

2 WALL & 3 WALL

WALK-IN SHOWER SYSTEMS

INSTALLATION AND OPERATING INSTRUCTIONS

Содержание SUMMER RAIN

Страница 1: ...SUMMER RAIN 2 WALL 3 WALL WALK IN SHOWER SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS...

Страница 2: ...user satisfaction We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products Our warranty does not cover improper installation related problems IMPORTANT...

Страница 3: ...______________________________ 13 Rough in Reference ____________________________________________________________________ 14 Component Identification __________________________________________________...

Страница 4: ...Whirlpool Bath s responsibility for shipping damage ceases upon delivery of the products in good order to the carrier Refer any claims for damage to the carrier For definitions of warranty coverage an...

Страница 5: ...WALL ROUGH IN REFERENCE 60 42 5 16 33 3 4 27 15 16 84 23 21 1 2 FRONT VIEW TOP VIEW 1 2 RIGID COPPER PIPE UNDER BASE COLD SUPPLY 1 1 2 TILE FLANGE HOT SUPPLY MINIMUM WATER PRESSURE FOR THE SYSTEM IS 4...

Страница 6: ...T CURVED GLASS WALL MOUNTING POST TOWER WITH PLUMBING FIXTURES MAGNETIC GASKET BOTTOM PLATE AND TOP COVER PREASSEMBLED GLAZING GASKET 3 TOWER MOUNTING BOLT WASHER CURVED GLASS FRONT RAIL GLASS PANEL S...

Страница 7: ...of a joint or splice of subfloor should be level to each other Level and support waste pipe cutout area greater than 5 x 5 The base is NOT to be supported by the tile flange INSTALLATION INSTRUCTIONS...

Страница 8: ...xcluded from the Jacuzzi Whirlpool Bath warranty Replace the strainer and tape over the drain hole to prevent finishing material from entering drain STEP 4 With the drain fitting passing over the cent...

Страница 9: ...aling the tile grout will prevent this leakage CLEAN UP AFTER INSTALLATION To avoid dulling and scratching the acrylic surface of the base never use abrasive cleaners A mild liquid detergent and warm...

Страница 10: ...heads STEP 3A Slide straight glass panel all the way into wall post Mark position of glass post Remove panel 2 WALL TOWER FIXED WALL AND CURVED GLASS INSTALLATION TAPE 6 PLACES FINISH WALL 3 4 19 mm E...

Страница 11: ...e of the tower 2 WALL TOWER FIXED WALL AND CURVED GLASS INSTALLATION NOTCH WASHER BOLT 5 16 GLAZING CHANNEL GLASS PANEL SUPPORT RAIL TOWER SUPPORT RAIL STEP 7 Insertsupportrailsintobracketsintopmouldi...

Страница 12: ...ith a 3 16 bit and secure bracket with screws and wall anchors provided STEP 10 Adjust the rails until tower is vertical in 2 planes 2 WALL TOWER FIXED WALL AND CURVED GLASS INSTALLATION STEP 12 Tight...

Страница 13: ...port rail Screw M3 5X9 5 mm screw into hole STEP 14 Install cover cap on fixed glass wall post STEP 15 Install glazing gasket on curved glass wall post on the outside Note orientation of gasket Soapy...

Страница 14: ...n Insert cover at top first STEP 18 Seal all around the base of tower with silicone sealant Also seal the inside of both wall posts glass post and the bottom of both glass panels on the inside only TO...

Страница 15: ...zi Whirlpool Bath s responsibility for shipping damage ceases upon delivery of the products in good order to the carrier Refer any claims for damage to the carrier For definitions of warranty coverage...

Страница 16: ...L ROUGH IN REFERENCE 60 42 5 16 33 3 4 27 15 16 84 23 21 1 2 FRONT VIEW TOP VIEW 1 2 RIGID COPPER PIPE UNDER BASE COLD SUPPLY 1 1 2 TILE FLANGE HOT SUPPLY MINIMUM WATER PRESSURE FOR THE SYSTEM IS 40PS...

Страница 17: ...D GLASS WALL MOUNTING POST TOWER WITH PLUMBING FIXTURES MAGNETIC GASKET BOTTOM PLATE AND TOP COVER PREASSEMBLED TOWER MOUNTING BOLT WASHER CURVED GLASS GLAZING GASKET 2 FRONT RAIL BRACKET COVER 2 WALL...

Страница 18: ...ve the stainless steel strainer from the drain assembly Disassemble the locknut and two gaskets from the back of the drain assembly Apply a 1 4 bead ofcaulking silicone tothedrainholeandinsertthedrain...

Страница 19: ...ng drain STEP 4 With the drain fitting passing over the center of the drainpipe lower the shower base carefully into place push down firmly until the base is in place You must check the level of the b...

Страница 20: ...d or blocking shims MUST be used to prevent distortion or cracking of the flange STUD CEMENT BOARD 1 4 MINIMUM GAP SILICONE SEALANT TILE TILE ADHESIVE 1 4 MINIMUM GAP SILICONE SEALANT STUD CEMENT BOAR...

Страница 21: ...lesandsecure with wall anchors and screws provided Cut a 12 strip of tape provided and apply firmly over screw heads FINISH WALL 3 4 19 mm TAPE 3 PLACES STEP 3 Slide the glass panel into the wall post...

Страница 22: ...MOUNTING BRACKET MOUNTING BRACKET COVER RAIL STEP 7 Place the front rail and tower support rail against the walls Check level and mark the position for the rail mounting bracket The screw position wi...

Страница 23: ...supply lines when connecting SHUT OFF VALVES PROVIDED COLD HOT BOLT STEP 11 Install cover cap on wall post STEP 12 Install glazing gasket on curved glass wall post on the outside Note orientation of g...

Страница 24: ...ED GLASS INSTALLATION TOWER COVER INSERT THIS SIDE FIRST TOWER COVER TOWER TOP PLATE STEP 15 Seal all around the base of tower with silicone sealant Also seal the inside of both wall posts bottom of b...

Страница 25: ...ed to change the direction of the spray Diverter Control To turn On water turn the inner knob clockwise and adjust for more or less flow The outer knob will divert the water to body sprays shower head...

Страница 26: ...and remove filter from the hose Clean any debris Reinstallation is the reverse of removal Turn on hot and cold supply and check for leaks Printed in U S A 2002 Jacuzzi Whirlpool Bath U223000 8 13 04 P...

Страница 27: ...hick 9 G432000 Nipple 1 2 Close 10 U217827 Shower Head Chrome 11 U215827 Jet Wall Body Chrome 12 U219827 Face Plate Transfer Valve Chrome 13 U546827 Nut Transfer Valve Chrome 14 U545827 Collar Transfe...

Страница 28: ...11 U827000 2X Ball Valve 5 FTP X 5 MPT L 12 U421000 11X Washer FTG 7 OD 13 U401000 7X FTG Ell 1 2 FST X 10mm Barb 14 U405000 L 4 5 Tubing PVC Reinforced 10mm Barb 15 U404000 2X FTG Y 10mm X 10mm X 10...

Страница 29: ...00 Glass Panel Front Wlak in 13 U354000 Screw Self Tap 8 X 1 25 L 14 U703000 Anchor 6 8 10 15 5374832 Screw Sheet Metal PHP 6 X 88 L 16 U196000 Bracket Corner Post Bottom 17 3952832 Bolt Hex FL Thrd 5...

Страница 30: ...0 U159000 Gasket Vinyl Glass Panel 11 J686000 Tape High Bond 2 Sided 12 U354000 Screw Self Tap 8 1 25 L 13 U703000 Anchor 6 8 10 14 3952832 Bolt Full Thread 5 16 15 3983832 Washer 5 16 Flat Type 2 Pln...

Страница 31: ...ESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss of use etc including its own negligence damages to respecting or resulting f...

Страница 32: ...as TX 75370 2168 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write t...

Отзывы: